Specifications for storage prior to installation
or use
When a system, a unit or a spare part has been delivered to the customer, it may be
subject to long time storage prior to installation and use.
General specifications
During this storage period, certain specifications must be met. The equipment must be
preserved and stored in such a way that it does not constitute any danger to health,
environment or personal injury.
1
The equipment must be stored in its original transportation box.
2
Ensure that the units are clearly separated in the shelves and that each unit is
easily identifiable.
3
The box must not be used for any purpose for which it was not intended (work
platform, steps, table etc.).
4
Boxes must not be placed on top of each other, unless specific markings permit this.
5
Boxes must not be placed directly on a dirt floor.
6
Do not open a box for inspection unless special circumstances permit so.
“Special circumstances” may be suspected damage to the box and its content, or
inspections by civil authorities.
a
If a unit is damaged, prepare an inspection report stating the condition of the
unit and the actions taken. Describe the damage and collect photographic
evidence if possible. Re-preserve the equipment.
b
If the unit is not damaged, check the humidity absorbing material. If required,
dry or replace the bags, then re-pack the unit according to the packing
instructions.
7
If a box has been opened, make sure that is it closed and sealed after the inspection.
Use the original packing material as far as possible.
8
The storage room/area must be dry with a non-condensing atmosphere. It must
be free from corrosive agents.
9
The storage room/area’s mean temperature must not be lower than -10° C, and
not warmer than +50° C. If other limitations apply, the crates will be marked
accordingly.
10
Boxes must not be exposed to moisture from fluid leakages.
11
Boxes must not be exposed to direct sunlight or excessive warmth from heaters.
12
Boxes must not be subjected to excessive shock and vibration.
13
If the unit contained in a box holds normal batteries, these may have been
disconnected/isolated before the unit was packed. These must only be reconnected
before the installation starts. Units containing batteries are marked.
KONGSBERG EM 2040 MKII Installation Manual
Содержание EM 2040 MKII
Страница 8: ...8 472405 A KONGSBERG EM 2040 MKII...
Страница 92: ...92 472405 A Related topics List of cables page 101 KONGSBERG EM 2040 MKII Installation Manual...
Страница 107: ...472405 A 107 Related topics Cable plan Hydrographic Work Station page 100 Cable layout and interconnections...
Страница 177: ...472405 A 177 338208 RX transducer outline dimensions 0 7 degrees Drawing file...
Страница 178: ...178 472405 A 338207 TX transducer outline dimensions 0 7 degrees KONGSBERG EM 2040 MKII Installation Manual...
Страница 179: ...472405 A 179 337805 TX transducer outline dimensions 0 4 degrees Drawing file...
Страница 180: ...180 472405 A 353631 Transducer mounting plate 0 7 x 0 7 degrees KONGSBERG EM 2040 MKII Installation Manual...
Страница 181: ...472405 A 181 355913 Transducer mounting plate 0 4 x 0 7 degrees Drawing file...
Страница 182: ...182 472405 A 359252 Baffle plate 0 7 x 0 7 degrees KONGSBERG EM 2040 MKII Installation Manual...
Страница 183: ...472405 A 183 385422 Processing Unit dimensions Drawing file...
Страница 184: ...184 472405 A 424178 Portable Processing Unit dimensions KONGSBERG EM 2040 MKII Installation Manual...
Страница 185: ...472405 A 185 464618 HWS dimensions MC330 Rack model Drawing file...
Страница 186: ...186 472405 A 475694 HWS dimensions MC330 Desktop model KONGSBERG EM 2040 MKII Installation Manual...
Страница 187: ...472405 A 187 370275 Remote Control Unit K REM dimensions Drawing file...
Страница 188: ...188 472405 A 373962 Remote Control Unit K REM wiring diagram KONGSBERG EM 2040 MKII Installation Manual...
Страница 247: ......
Страница 248: ...2021 Kongsberg Maritime...