![Kondo 2500 Series Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/kondo/2500-series/2500-series_instruction-manual_1992319009.webp)
9
■ Damping :Changing the damping alters the level of braking applied to the servo. A small setting increases the
level of braking applied to a rotating servo, slowing it down just before it reaches the position it was
moving to. A larger setting reduces this braking effect, but increases the chance of the servo
overshooting and rotating further than it meant to.
( Range: 1 is the weakest. 255 is the strongest. )
■ Protection:When the servos detect a locked out condition, they will go into protection mode and shut down to
save the motors from burning out. This setting sets the amount of time before the servos go into
protection mode. The bigger the number, the longer they will wait before going into protection mode.
( Value range: 10 is the shortest. 255 is the longest. )
■ Limiter (normal rotation) :You can set the maximum range of movement for normal rotation.
( Value range: Minimum 8000 Maximum 11500.)
■ Limiter (reverse rotation):You can set the maximum range of movement for reverse rotation.
( Value range: Minimum 3500 Maximum 7000.)
■ Temperature restriction :This mode enables a limit to be placed on the electrical current. Setting a higher value
raises the maximum electrical current threshold. If an electrical current greater than the set threshold
is detected, the limiter will come into effect and restrict the current to the maximum set by the user.
( Range: The highest threshold is 1. The lowest threshold is 127.)
■ Current restriction :This mode enables a limit to be placed on the electrical current. Setting a higher value raises
the maximum electrical current threshold. If an electrical current greater than the set threshold is
detected, the limiter will come into effect and restrict the current to the maximum set by the user.
( Range: The lowest current is 1. The highest current is 63.)
■User offset:This enables the user to trim the starting position of the servos.
( Range: From -127 of reverse rotation to 127 of normal rotation.)
■Firmware version:Displays information about the servo firmware. Firmware cannot be updated by the user.