MAINTENANCE
MAINTENANCE PROCEDURE
CHECK AND MAINTENANCE AIR CONDITIONER
Check Level of Refrigerant (gas)
WARNING
If the refrigerant used in the air conditioner gets into your eyes or on your hands, it may cause loss of sight or frostbite. Do not
touch the refrigerant. Never loosen any part of the refrigerant circuit.
Do not bring any flame close to any point where the refrigerant gas is leaking.
If the level of the refrigerant (gas) is low, the cooling effect will be
reduced. Run the engine at high idle, and check the flow of the
refrigerant gas (R134a) in the refrigerant circuit through the sight
glass (2) (inspection window) of the receiver (1) when the cooler is
running at high speed.
(A) No bubbles in refrigerant flow: Suitable
(B) Some bubbles in flow (bubbles pass continuously):
Lack of refrigerant
(C) Colorless, transparent: No refrigerant
REMARK
When there are bubbles, the refrigerant gas level is low, so contact
your Komatsu distributors to have refrigerant added. If the air
conditioner is run with the refrigerant gas level low, it will cause
damage to the compressor.
Inspection During Off Season
Even during the off-season, operate the air conditioner for 3 to 5 minutes once a month to maintain the oil film at all
parts of the compressor.
Inspection and Maintenance Items
Check, maintenance items
Content of check, maintenance
Guideline for maintenance
interval
Refrigerant (gas)
Charge amount
Twice a year (spring, autumn)
Air conditioner condenser
Clogged fins
Every 500 hours
Compressor
Operating condition
Every 4000 hours
V-belt
Damage, tension
Every 250 hours
Blower motor, fan
Operating condition
(does it make abnormal noise?)
When required
Control mechanism
Operating condition (does it function normally?)
When required
Piping mounts
Mounting condition, looseness at tightening or
connecting portions, leakage of gas, damage
When required
4 - 39
Содержание PC300-8
Страница 2: ...1 1...
Страница 12: ...2 1...
Страница 55: ......
Страница 56: ...3 1...
Страница 264: ...4 1...
Страница 312: ...MAINTENANCE MAINTENANCE PROCEDURE MAINTENANCE MAINTENANCE PROCEDURE 7 Boom foot pin 2 places 4 49...
Страница 347: ......
Страница 348: ...5 1...
Страница 351: ......
Страница 352: ...6 1...