MAINTENANCE PLAN
169
2 - Remove the screws (2) that hold the filter cover (3), remove
the cartridge (4) and the filter casing (5).
Use a 13 mm spanner.
3 - Carefully clean the filter casing (5), making sure that the filter
gasket (7) and the container gasket (8) are in perfect condi-
tions.
4 - Change the cartridge (4).
5 - Reassemble all the components proceeding in the reverse or-
der and making sure that the gasket (6) of the cover (3) is
sound and correctly positioned in the cover seat.
6 - Close the side cover.
IMPORTANT
☞
•
The hydraulic oil used in machines provided with demoli-
tion hammer deteriorates sooner than the oil used in ma-
chines that carry out only normal digging operations.
On new machines the filter must be changed after the first
100-150 hours of operation, while the successive changes
must be carried out according to the intervals indicated on
table beside.
•
If the machine contains synthetic biodegradable oil type
HEES, the filter must be changed after the first 50 hours of
operation.
0
20
40
60
80
100
500
100
800
Breaker operating
ratio (%)
Replacement
interval (H)
Replacement interval
for element
RWA10710
2
3
4
5
7
8
6
RYA14480
Содержание PC110R-1
Страница 2: ......
Страница 19: ...17 SAFETY AND ACCIDENT PREVENTION...
Страница 51: ...49 THE MACHINE AND ITS OPERATIONS...
Страница 126: ...124 PAGE INTENTIONALLY LEFT BLANK...
Страница 127: ...125 MAINTENANCE...
Страница 190: ...188 PAGE INTENTIONALLY LEFT BLANK...
Страница 191: ...189 TECHNICAL SPECIFICATIONS...
Страница 198: ...196 PAGE INTENTIONALLY LEFT BLANK...
Страница 199: ...197 AUTHORISED OPTIONAL EQUIPMENT...