MAINTENANCE PLAN
143
4.7.9 MAINTENANCE EVERY 250 HOURS OF OPERATION
4.7.10 MAINTENANCE AFTER THE FIRST 500 HOURS OF OPERATION
(Only for machines in which the synthetic biodegradable oil type
HEES is used)
(Carry out these operations together with those to be performed every 500
HOURS, see “4.7.11 MAINTENANCE EVERY 500 HOURS OF OPERATION”)
4.7.11 MAINTENANCE EVERY 500 HOURS OF OPERATION
N.
PART
OPERATION
PAGE
a
Fan belt
Check fan belt condition and tension
164
b
A/C compressor belt
(only for machines with air conditioner)
Check fan belt condition and tension
165
c
Battery
Check electrolyte level
166
d
Travel reduction gears
Check levels (n. 2)
166
e
Swing reduction gear
Check level (n. 1)
167
N.
PART
OPERATION
PAGE
a
Hydraulic oil and suction filter
(Only for machines with synthetic biodegrada-
ble oil)
Change oil and clean filter
181
N.
PART
OPERATION
PAGE
a
Hydraulic oil drainage filter
Change cartridge
168
b
Servo control filter
Change cartridge
170
c
Engine oil
Change
171
d
Engine oil filter
Change
172
e
Fuel filter
Change cartridge
173
f
Fuel tank
Drain condensate
174
g
Radiators
Clean outside
174
h
A/C condenser
(only for machines with air conditioner)
Clean outside
175
j
Ball-bearing ring pinion
Check lubricant and top up
176
k
Hydraulic oil tank
(Only for machines with synthetic biodegrada-
ble oil)
Drain condensate
176
Содержание PC110R-1
Страница 2: ......
Страница 19: ...17 SAFETY AND ACCIDENT PREVENTION...
Страница 51: ...49 THE MACHINE AND ITS OPERATIONS...
Страница 126: ...124 PAGE INTENTIONALLY LEFT BLANK...
Страница 127: ...125 MAINTENANCE...
Страница 190: ...188 PAGE INTENTIONALLY LEFT BLANK...
Страница 191: ...189 TECHNICAL SPECIFICATIONS...
Страница 198: ...196 PAGE INTENTIONALLY LEFT BLANK...
Страница 199: ...197 AUTHORISED OPTIONAL EQUIPMENT...