3.
Check if preheating pilot lamp (3) on the machine monitor
is lit.
4.
Leave this condition until preheating pilot lamp (3) goes
out.
The lighting time of preheating pilot lamp (3) varies with
the ambient temperature as shown in the table.
Ambient temperature
( °C { °F} )
Lighting time (sec.)
-3 to -10 {27 to 14}
5 to 15
-10 to -20 {14 to -4}
15 to 32
-20 to -30 {-4 to -22}
32 to 45
5.
After preheating pilot lamp (3) goes out, turn the key of
starting switch (2) to START position (C), and start the en-
gine.
6.
When the engine starts, release the starting switch key (2).
The key will return automatically to ON position (B).
REMARK
Just after starting the engine, run it at low idle. During this
period, release the decelerator/brake pedal and perform
no operation of the work equipment.
7.
When the engine speed is stabilized, set the fuel control
dial back to Low idle (MIN) position, and perform the
warm-up operation.
OPERATION
MACHINE OPERATIONS AND CONTROLS
3-191
Содержание D61EX-24
Страница 51: ......
Страница 52: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1 ...
Страница 212: ...3 After checking turn the starting switch back to OFF posi tion A OPERATION MACHINE OPERATIONS AND CONTROLS 3 161 ...
Страница 221: ...3 Return the starting switch back to OFF position A MACHINE OPERATIONS AND CONTROLS OPERATION 3 170 ...
Страница 313: ......
Страница 314: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1 ...
Страница 398: ...SPECIFICATIONS 5 1 ...
Страница 401: ......
Страница 417: ......
Страница 418: ...REPLACEMENT PARTS 7 1 ...
Страница 427: ......
Страница 435: ...D61EX 24 D61PX 24 BULLDOZER Form No TEN00709 03 2017 KOMATSU All Rights Reserved Printed in Japan 03 2017 ...