CAUTION

When the air filter is to be 
removed, do not touch the 
metal parts of the unit.

It may cause an injury.

Do not clean unit when 
power is on as it may cause 
fire and electric shock, it may
cause an injury.

Operation with windows 
opened may cause wetting
of indoor and soaking of 
household furniture.

When the unit is to be 
cleaned, switch off, and turn
off the circuit breaker.

Stop operation and close 
the window in storm or 
hurricane.

Use caution when unpacking and 
installing. Sharp edges could cause injury.

Do not clean the air 
conditioner with water.

Water may enter the unit and 
degrade the insulation. It may 
cause an electric shock.

This could injure the pet or
plant.

It may cause electric shock 
and damage.

Do not put a pet or house 
plant where it will be
exposed to direct air flow.

Hold the plug by the head 
of the power plug when 
taking it out.

Ventilate the room well when
used together with a stove, 
etc.

An oxygen shortage may occur.

Do not use this air conditioner to 

preserve precision devices, food,

pets, plants, and art objects.

It may cause deterioration of 

quality, etc. 

It may cause failure of product 

or fire.

Do not use for special 
purposes.

Turn off the main power  
switch when not using the
unit for a long time.

If water enters the unit, turn the unit off at the power 
outlet and switch off the circuit breaker. Isolate 
supply by taking the power-plug out and contact a 
qualified service technician.

!!

! !

! !

! !

! !

! !

! !

It may cause failure of 
appliance or accident.

Appearance may be 
deteriorated due to change
of product color or 
scratching of its surface.

Do not place obstacles 
around air-inlets or inside 
of air-outlet.

Do not use strong deter-
gent such as wax or 
thinner but use a soft cloth.

If bracket is damaged, there
is concern of damage due to
falling of unit.

There is danger of fire or 
electric shock.

Ensure that the installation bracket of 
the outdoor appliance is not damaged 
due to prolonged exposure.

Do not place heavy object on the 
power cord and ensure that the cord
is not compressed.

Operation without filters may

cause failure.

It contains contaminants and 

could make you sick.

Always insert the filters 
securely. Clean filter once 
every two weeks.

Do not drink water drained 
from air conditioner.

! !

! !

! !

2

2

Содержание KAM-75BMC

Страница 1: ...ual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner ple...

Страница 2: ... established collection systems where electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least free of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wild disp...

Страница 3: ...all be installed in accordance with national wiring regulations Donot operate your air conditioner in a wet room such as a bathroom or laundry room The appliance with electric heater shall have at least 1 meter space to the combustible materials Contact the authorised service technician for repair or maintenance of this unit Contact the authorised installer for installation of this unit If the air...

Страница 4: ...CONTENTS 1 SAFETY PRECAUTIONS 1 2 UNIT PARTS IDENTIFICATION 4 3 OPERATING INSTRUCTIONS 5 4 INSTALLATION INSTRUCTIONS 9 5 TROUBLESHOOTING TIPS 13 6 SPECIFICATIONS 14 ...

Страница 5: ...or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire and electric shock It may cause fire and electric shock It may cause electric shock or fire If the power cord is damaged it must be replaced by the manufac turer or an authorised service centre or a similarly qualified per son in order to avoid a hazard This could damage y...

Страница 6: ...s food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified service techni...

Страница 7: ...ing devices 3 Do not use this air conditioner for non specified special purposes e g Preserving precision devices food pets plants and art objects Usage in such a manner could harm such property 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy t...

Страница 8: ...reliable earth wire 4 The unit should be provided with an individual circuit and the circuit breaker fuse rating should be the same as that of the power cord and wall outlet POWER CORD A E N E Earth wire yellow green N Neutral wire blue A Active wire brown Fig a Fig b Wall outlet Air break switch 4 4 NOTE All the illustrations in the manual are for explanation purpose only Your air conditionar may...

Страница 9: ...ual are representative of many available models Your model may offer slightly different features Cool Mode The desired cool setting is selected by rotating the knob to the right to the appropriate location HIGH COOL has maximum cooling effect and airflow LOW COOL has minimum cooling effect and airflow MED COOL has the intermediate cooling effect and airflow OFF will completely shut off the unit TH...

Страница 10: ...hen the thermostat knob is rotated clockwise allow at least three minutes before turning back the knob to the COOLER direction Otherwise the fuse may blow due to an overload of the unit AUTO SWING OFF ON AUTO SWING on some models Horizontal air flow adjustment automatically When the AUTO SWING switch is turned to ON position the vertical louvers automatically oscillate right and left sweeping the ...

Страница 11: ...t in the CLOSED position during cooling for maximum cooling effect The OPEN position is used only for ventilation 7 7 The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks or as necessary to maintain optimal performance of the air conditioner Air Filter How to remove the air filter 1 Hold the slot under the front panel then uplift it outwards and remove t...

Страница 12: ... RUBBER PLUG SCREW DRAIN PAN DRAIN OUTLET Note When you choice bottom drainage the air conditioner will effect cooling efficiencylittle and have no voice of hit water When cooling you can choose back drainage on models with back drain hole See the following procedures to perform back drainage 1 Fit the seal onto the drain joint which provided with your air conditioner accessory 2 Remove the rubber...

Страница 13: ...WNING FENCE Step 1 Remove the air conditioner from it s packaging remove fixing screws and slide the air conditioner out of it s housing Refer to Installation Steps Step 2 Prepare the hole in the wall so that the bottom of the housing is well supported the top has minimum clearance and the air inlet louvers have clearance as shown below in options A and B Holes from the outside through to the cavi...

Страница 14: ...nd fit as per the Installation lnstruction 5 Switch unit on Check for operation of the unit and check for vibration in the installation 6 Fit the drain pan to the housing and run a drain line to a suitable location if required Alternative method of installation if external support cannot be provided FLASH OR SEAL AROUND EXTERNAL WALL FRAME OR ARCHITRAVE STURDY TIMBER FRAME TIMBER FRAMED WALL OR PA...

Страница 15: ...kinds of emoving the frame Remove the four screws located on both sides and the back of the cabinet as shown in Fig 3A Remove one screw on the chassis fixing bracket then remove the chassis fixing bracket Remove the two screws located on the back of the cabinet as shown in Fig 3B Remove the two screw on the letf and right chassis fixing brackets then remove the two chassis fixing brackets as shown...

Страница 16: ... wait 3 minutes before restarting Thermostat set too low Adjust thermostat to higher number for cooling Step 3 Installation 1 Grasp the handle on the chassis and carefully slide the air conditioner out of the cabinet See Fig 5 2 Remove shipping pad from around compressor before operation and make sure the discharge points to the drain pan are aligned before the chassis is pushed into the cabinet S...

Страница 17: ...e Air conditioner cooling but room is too warm NO ice forming on cooling coil behind decorative front Thermostat set too warm Turn thermostat clockwise to a colder setting Air directional louvers positioned improperly Position louvers for better air distribution Front of units is blocked by drapes blinds furniture etc restricts air distribution Clear blockage in front of unit Doors windows registe...

Страница 18: ... Minimum Wire Size AWG American Wire Gage Appliance Amps AWG Wire Size 10 13 18 25 18 16 14 12 30 10 NOTE Value of D is only referenced 3 and 6 6 and 10 10 and 16 16 and 25 MODEL Btu h BODY DIMENSION mm W X H X D 5000 6000 445X320X415 450X346X535 15000 16000 560X400X640 660X434X620 660X428X680 15000 24000 660X428X780 7000 9000 450X346X535 9000 12000 600X380X560 450X346X585 ...

Страница 19: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details KPII20190423 ...

Отзывы: