1. To avoid vibration and noise, make sure the unit is installed securely and firmly.
2. Install the unit where the sunlight does not shine directly on the unit.

If the unit receives direct sunlight, build an awning to shade the cabinet.

3. There should be no obstacle, such as a fence or wall, within 50cm from the back of the

cabinet because it will prevent  heat radiation of the condenser.
Restriction of outside air will greatly reduce the cooling and heating efficiency of the 
air conditioner.

4. Install the unit a little obliquely outward not to leak the condensed water into the room

O

(about 3~4  with level).

5. Install the unit with its bottom portion 75~150cm above the floor level.
6. The power cord must be connected to an independent circuit. The yellow/green

wire must be grounded.

All side louvers of the cabinet must remain exposed to the outside of the structure.

CAUTION

Select the best location 

INSTALLATION INSTRUCTIONS 

75~150cm

Over 50cm

O

About 3~4

AWNING

FENCE

75

~150cm

Over 50cm

O

About 3~4

AWNING

FENCE

Step 1
Remove the air conditioner from it's packaging, remove fixing
screws and slide the air conditioner out of it's housing (Refer
to Installation Steps).
Step 2
Prepare the hole in the wall so that the bottom of the housing 
is well supported, the top has minimum clearance and the air 
inlet louvers have clearance as shown below in options  A and
B. Holes from the outside through to the cavity should be 
sealed. The housing should slope down towards the rear by 
about 5mm to allow water formed during operation to drain.
Step 3
Install the housing into the wall and secure. Ensure the foam
seals are not damaged. Flash, seal or fill gaps around the 
inside and outside to provide satisfactory appearance and 
protection against the weather, insects and rodents.

Installation of the Housing 

NOTE: UNIT MAY BE SUPPORTED BY A 

  SOLID FRAME FROM BELOW OR 
  BY A HANGER FROM A SOLID
  OVERHEAD SUPPORT.

Preferred method of installation into a timber 
framed wall, partition or window.

FLASH OR SEAL AROUND EXTERNAL 
WALL FRAME OR ARCHITRAVE

STURDY TIMBER
FRAME ALL ROUND 
UNIT

TIMBER FRAMED 
WALL OR PARTITION

EXTERNAL SUPPORT 
FRAME AT BALANCE
POINT OF A/C

ALTERNATIVELY, BRACKETS 
AS ILLUSTRATED BELOW
MAY BE USED.

DRAIN PAN

Содержание KAM-75BMC

Страница 1: ...ual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner ple...

Страница 2: ... established collection systems where electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least free of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wild disp...

Страница 3: ...all be installed in accordance with national wiring regulations Donot operate your air conditioner in a wet room such as a bathroom or laundry room The appliance with electric heater shall have at least 1 meter space to the combustible materials Contact the authorised service technician for repair or maintenance of this unit Contact the authorised installer for installation of this unit If the air...

Страница 4: ...CONTENTS 1 SAFETY PRECAUTIONS 1 2 UNIT PARTS IDENTIFICATION 4 3 OPERATING INSTRUCTIONS 5 4 INSTALLATION INSTRUCTIONS 9 5 TROUBLESHOOTING TIPS 13 6 SPECIFICATIONS 14 ...

Страница 5: ...or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire and electric shock It may cause fire and electric shock It may cause electric shock or fire If the power cord is damaged it must be replaced by the manufac turer or an authorised service centre or a similarly qualified per son in order to avoid a hazard This could damage y...

Страница 6: ...s food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified service techni...

Страница 7: ...ing devices 3 Do not use this air conditioner for non specified special purposes e g Preserving precision devices food pets plants and art objects Usage in such a manner could harm such property 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy t...

Страница 8: ...reliable earth wire 4 The unit should be provided with an individual circuit and the circuit breaker fuse rating should be the same as that of the power cord and wall outlet POWER CORD A E N E Earth wire yellow green N Neutral wire blue A Active wire brown Fig a Fig b Wall outlet Air break switch 4 4 NOTE All the illustrations in the manual are for explanation purpose only Your air conditionar may...

Страница 9: ...ual are representative of many available models Your model may offer slightly different features Cool Mode The desired cool setting is selected by rotating the knob to the right to the appropriate location HIGH COOL has maximum cooling effect and airflow LOW COOL has minimum cooling effect and airflow MED COOL has the intermediate cooling effect and airflow OFF will completely shut off the unit TH...

Страница 10: ...hen the thermostat knob is rotated clockwise allow at least three minutes before turning back the knob to the COOLER direction Otherwise the fuse may blow due to an overload of the unit AUTO SWING OFF ON AUTO SWING on some models Horizontal air flow adjustment automatically When the AUTO SWING switch is turned to ON position the vertical louvers automatically oscillate right and left sweeping the ...

Страница 11: ...t in the CLOSED position during cooling for maximum cooling effect The OPEN position is used only for ventilation 7 7 The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks or as necessary to maintain optimal performance of the air conditioner Air Filter How to remove the air filter 1 Hold the slot under the front panel then uplift it outwards and remove t...

Страница 12: ... RUBBER PLUG SCREW DRAIN PAN DRAIN OUTLET Note When you choice bottom drainage the air conditioner will effect cooling efficiencylittle and have no voice of hit water When cooling you can choose back drainage on models with back drain hole See the following procedures to perform back drainage 1 Fit the seal onto the drain joint which provided with your air conditioner accessory 2 Remove the rubber...

Страница 13: ...WNING FENCE Step 1 Remove the air conditioner from it s packaging remove fixing screws and slide the air conditioner out of it s housing Refer to Installation Steps Step 2 Prepare the hole in the wall so that the bottom of the housing is well supported the top has minimum clearance and the air inlet louvers have clearance as shown below in options A and B Holes from the outside through to the cavi...

Страница 14: ...nd fit as per the Installation lnstruction 5 Switch unit on Check for operation of the unit and check for vibration in the installation 6 Fit the drain pan to the housing and run a drain line to a suitable location if required Alternative method of installation if external support cannot be provided FLASH OR SEAL AROUND EXTERNAL WALL FRAME OR ARCHITRAVE STURDY TIMBER FRAME TIMBER FRAMED WALL OR PA...

Страница 15: ...kinds of emoving the frame Remove the four screws located on both sides and the back of the cabinet as shown in Fig 3A Remove one screw on the chassis fixing bracket then remove the chassis fixing bracket Remove the two screws located on the back of the cabinet as shown in Fig 3B Remove the two screw on the letf and right chassis fixing brackets then remove the two chassis fixing brackets as shown...

Страница 16: ... wait 3 minutes before restarting Thermostat set too low Adjust thermostat to higher number for cooling Step 3 Installation 1 Grasp the handle on the chassis and carefully slide the air conditioner out of the cabinet See Fig 5 2 Remove shipping pad from around compressor before operation and make sure the discharge points to the drain pan are aligned before the chassis is pushed into the cabinet S...

Страница 17: ...e Air conditioner cooling but room is too warm NO ice forming on cooling coil behind decorative front Thermostat set too warm Turn thermostat clockwise to a colder setting Air directional louvers positioned improperly Position louvers for better air distribution Front of units is blocked by drapes blinds furniture etc restricts air distribution Clear blockage in front of unit Doors windows registe...

Страница 18: ... Minimum Wire Size AWG American Wire Gage Appliance Amps AWG Wire Size 10 13 18 25 18 16 14 12 30 10 NOTE Value of D is only referenced 3 and 6 6 and 10 10 and 16 16 and 25 MODEL Btu h BODY DIMENSION mm W X H X D 5000 6000 445X320X415 450X346X535 15000 16000 560X400X640 660X434X620 660X428X680 15000 24000 660X428X780 7000 9000 450X346X535 9000 12000 600X380X560 450X346X585 ...