Vertical air flow adjustment (manually)

To adjust vertical air flow direction, adjust any one of the 
horizontal louver blades. When turning up or down the 
horizontal louver blades, always keep horizontality the top 
or bottom blades. This can effectively prevent water drops 
condensed on the front panel of the unit.

Vent Control

The vent control is located above the control knobs. The operation method is different
 on different models (see the following figures).
For maximum cooling efficiency, CLOSE the vent. This will allow internal air circulation. 
OPEN the vent to discharge stale air.

CLOSE       VENT       OPEN

To open the vent, pull the lever toward you 
To close it, push it in.

To open the vent, set the lever to the right position 
To close it, set the lever in the left position.

CLOSE         OPEN

NOTE: The VENTILATION LEVER should normally be kept in the CLOSED position during
 cooling for maximum cooling effect. The "OPEN" position is used only for ventilation. 

7

7

The air filter behind the inlet grille should be checked and 
cleaned at least once every 2 weeks (or as necessary) to 
maintain optimal performance of the air conditioner. 

Air Filter

How to remove the air filter

1. Hold the slot under the front panel, then uplift it outwards,
    and remove the front panel.
2. Pinch the handle under the air filter and make the air filter
    arched, remove it from the slot from underside to upside.
3. Clean the filter with warm, soapy water. The water

O

    should be below 40 C to prevent distortion of the filter.
4. Rinse off and gently shake off excess water from the
    filter. Allow the filter to dry before replacing it. To prevent
    distortion of the filter, do not dry in direct sunlight. 

NOTET:Be sure to unplug the unit before cleaning to 
prevent chock or fire hazards.

NEVER operate the air conditioner without the 
air filter, as dust/dirt particles can contribute to 
equipment failure.

CAUTION

!

!

Содержание KAM-75BMC

Страница 1: ...ual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner ple...

Страница 2: ... established collection systems where electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least free of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wild disp...

Страница 3: ...all be installed in accordance with national wiring regulations Donot operate your air conditioner in a wet room such as a bathroom or laundry room The appliance with electric heater shall have at least 1 meter space to the combustible materials Contact the authorised service technician for repair or maintenance of this unit Contact the authorised installer for installation of this unit If the air...

Страница 4: ...CONTENTS 1 SAFETY PRECAUTIONS 1 2 UNIT PARTS IDENTIFICATION 4 3 OPERATING INSTRUCTIONS 5 4 INSTALLATION INSTRUCTIONS 9 5 TROUBLESHOOTING TIPS 13 6 SPECIFICATIONS 14 ...

Страница 5: ...or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire and electric shock It may cause fire and electric shock It may cause electric shock or fire If the power cord is damaged it must be replaced by the manufac turer or an authorised service centre or a similarly qualified per son in order to avoid a hazard This could damage y...

Страница 6: ...s food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified service techni...

Страница 7: ...ing devices 3 Do not use this air conditioner for non specified special purposes e g Preserving precision devices food pets plants and art objects Usage in such a manner could harm such property 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy t...

Страница 8: ...reliable earth wire 4 The unit should be provided with an individual circuit and the circuit breaker fuse rating should be the same as that of the power cord and wall outlet POWER CORD A E N E Earth wire yellow green N Neutral wire blue A Active wire brown Fig a Fig b Wall outlet Air break switch 4 4 NOTE All the illustrations in the manual are for explanation purpose only Your air conditionar may...

Страница 9: ...ual are representative of many available models Your model may offer slightly different features Cool Mode The desired cool setting is selected by rotating the knob to the right to the appropriate location HIGH COOL has maximum cooling effect and airflow LOW COOL has minimum cooling effect and airflow MED COOL has the intermediate cooling effect and airflow OFF will completely shut off the unit TH...

Страница 10: ...hen the thermostat knob is rotated clockwise allow at least three minutes before turning back the knob to the COOLER direction Otherwise the fuse may blow due to an overload of the unit AUTO SWING OFF ON AUTO SWING on some models Horizontal air flow adjustment automatically When the AUTO SWING switch is turned to ON position the vertical louvers automatically oscillate right and left sweeping the ...

Страница 11: ...t in the CLOSED position during cooling for maximum cooling effect The OPEN position is used only for ventilation 7 7 The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks or as necessary to maintain optimal performance of the air conditioner Air Filter How to remove the air filter 1 Hold the slot under the front panel then uplift it outwards and remove t...

Страница 12: ... RUBBER PLUG SCREW DRAIN PAN DRAIN OUTLET Note When you choice bottom drainage the air conditioner will effect cooling efficiencylittle and have no voice of hit water When cooling you can choose back drainage on models with back drain hole See the following procedures to perform back drainage 1 Fit the seal onto the drain joint which provided with your air conditioner accessory 2 Remove the rubber...

Страница 13: ...WNING FENCE Step 1 Remove the air conditioner from it s packaging remove fixing screws and slide the air conditioner out of it s housing Refer to Installation Steps Step 2 Prepare the hole in the wall so that the bottom of the housing is well supported the top has minimum clearance and the air inlet louvers have clearance as shown below in options A and B Holes from the outside through to the cavi...

Страница 14: ...nd fit as per the Installation lnstruction 5 Switch unit on Check for operation of the unit and check for vibration in the installation 6 Fit the drain pan to the housing and run a drain line to a suitable location if required Alternative method of installation if external support cannot be provided FLASH OR SEAL AROUND EXTERNAL WALL FRAME OR ARCHITRAVE STURDY TIMBER FRAME TIMBER FRAMED WALL OR PA...

Страница 15: ...kinds of emoving the frame Remove the four screws located on both sides and the back of the cabinet as shown in Fig 3A Remove one screw on the chassis fixing bracket then remove the chassis fixing bracket Remove the two screws located on the back of the cabinet as shown in Fig 3B Remove the two screw on the letf and right chassis fixing brackets then remove the two chassis fixing brackets as shown...

Страница 16: ... wait 3 minutes before restarting Thermostat set too low Adjust thermostat to higher number for cooling Step 3 Installation 1 Grasp the handle on the chassis and carefully slide the air conditioner out of the cabinet See Fig 5 2 Remove shipping pad from around compressor before operation and make sure the discharge points to the drain pan are aligned before the chassis is pushed into the cabinet S...

Страница 17: ...e Air conditioner cooling but room is too warm NO ice forming on cooling coil behind decorative front Thermostat set too warm Turn thermostat clockwise to a colder setting Air directional louvers positioned improperly Position louvers for better air distribution Front of units is blocked by drapes blinds furniture etc restricts air distribution Clear blockage in front of unit Doors windows registe...

Страница 18: ... Minimum Wire Size AWG American Wire Gage Appliance Amps AWG Wire Size 10 13 18 25 18 16 14 12 30 10 NOTE Value of D is only referenced 3 and 6 6 and 10 10 and 16 16 and 25 MODEL Btu h BODY DIMENSION mm W X H X D 5000 6000 445X320X415 450X346X535 15000 16000 560X400X640 660X434X620 660X428X680 15000 24000 660X428X780 7000 9000 450X346X535 9000 12000 600X380X560 450X346X585 ...

Страница 19: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details KPII20190423 ...

Отзывы: