4.3 Setting of the Prism Constant
The default setting of prism constant for the total station is -30mm. If the constant of
the prism is not -30mm, you must change this setting. Once the prism constant is set ,it will
become the new default value until changed.
Operation Procedure
Operation
Display
①
Press star key into quick setting
Press
★
key
②
Press 1 key to choose Target
1
③
Input prism constant correction *1),
press ENT
Input data
*1) Refer to 2.10 “How to Enter Character”
Input range: -99.9mm to +99.9mm Step length 0.1mm
*The total station in reflectorless measuring mode sets the prism constant to 0 automatically.