114
5.Calculate the zero deviation of tilt sensor by using following formula:
Deviation X=(X1+X2)/2
Deviation Y=(Y1+Y2)/2
Adjustment
If the deviation value within ±20
″
, then no need adjustment, otherwise need adjustment
as following:
1.Enter Tilt adjustment page in Adjustment function
2.Collimate a target in the right position
3.Press (OK), collimate the same target in the reverse position
4. Confirm whether the adjustment correction value within the range. If X value and Y
value are within the adjustment range, then press F4 (OK) to update the correction value,
Содержание CTS-632R10M
Страница 9: ...4 Object Lens Battery EDM Trigger Key Horizontal Tangent Unit Circular Vial...
Страница 58: ...53 Press F4 coordinate key F4 Input the end point continue to measure To return to Menu press the ESC key...
Страница 78: ...73 10 5 Point Projection Measure 2 starting points P1 and P2 to define a straight line at first then measure a...
Страница 79: ...74 11 PROGRAM Normal measurement mode MENU 4...