121
Point B and Point C on the same line with the distance of 50m between each point. Set the
reflector accurately on each point when measuring.
2. After setting temperature and air pressure in the instrument measure the Horizontal
Distance of AB and AC accurately.
3. Set the instrument on Point B and center it accurately, measure the Horizontal Distance
of BC accurately.
4. Then you can calculate the Instrument Constant:K=AC-(AB+BC)
K should be very close to 0, If | K | > 5 mm the instrument should be inspected at a
standard baseline site and adjusted according the inspection value.
Adjustment
If a strict inspection proves that the Instrument Constant K has changed the operator can
change the constant by entering the adjustment amount. Press 3 in ADJUSTMENT mode and
key in the new constant.