AVV-711 Quick Book
40
Yellow clock face background means no angle currently accepted(or averaging not
complete yet) or rotating angle(to adjacent position) too small(lower than 6 degrees)
When blinks means connection to sensor not established
When blinks means no beam condition(beam does not reach target)
Presence of this image means extended Y values range used(offset present)
Crossed image means auto sweep mode disabled. Auto sweep not allowed for
vertical machines
Aligning type sign
H – horizontal
V = vertical
(flange machine)
Current reading index /
last reading index
from zero to N-1, where N =
total readings
( active)
Transducer(s) serial
number(s).
“no sensor” if data from
transducers not present
Angles from stationary and
movable side
Manual angle
Hint box
Auto sweep not allowed for
vertical machines
Rotation angle sector size,
must be more than 60
Clock face with readings
positions marked and
graphically showed angles
Beam position box