TP-5660 11/98
IV Safety Precautions and Instructions
Moving Parts
Hazardous voltage. Moving rotor.
Can cause severe injury or death.
Operate generator set only with all
guards and electrical enclosures in
place.
WARNING
Notice
NOTICE
Hardware damage!
Transfer switch
may use both American Standard and
metric hardware. Use the correct size
tools to prevent rounding of bolt heads
and nuts.
NOTICE
When replacing hardware, do not
substitute
with
inferior
grade
hardware.
Screws and nuts are
available in different hardness ratings.
American Standard hardware uses a
series of markings and metric hardware
uses a numeric system to indicate
hardness. Check markings on bolt
head and nuts for identification.
NOTICE
Improper operator handle usage!
Use the manual operator handle
provided on the transfer switch for
maintenance purposes only. Return
the transfer switch to the normal
position.
Remove manual operator
handle, if used, and store it on the
transfer switch in the place provided
when service is completed.
NOTICE
Foreign material contamination!
Cover
transfer
switch
during
installation to keep dirt, grit, metal drill
chips, etc., out of components. Cover
solenoid
mechanism
during
After installation, use
manual operating handle to position
contactor to ensure that it operates
freely. Do not use a screwdriver to
force contactor mechanism.
NOTICE
Electrostatic discharge damage!
Electrostatic
discharge
(ESD)
damages electronic circuit boards.
Prevent
electrostatic
discharge
damage by wearing an approved
grounding wrist strap when handling
electronic circuit boards or integrated
circuits. An approved grounding wrist
strap provides a high resistance (about
1 megohm),
not a direct short
, to
ground
.
Содержание ZCS series
Страница 16: ...TP 5660 11 98 8 Specifications Notes...
Страница 30: ...TP 5660 11 98 22 Diagrams and Drawings Notes...
Страница 31: ...TP 5660 11 98 Diagrams and Drawings 23 Enclosure Dimensions Drawing 40 260 Amp NEMA Type 1 and Type 3R ADV 6180...
Страница 32: ...24 Diagrams and Drawings TP 5660 11 98 Enclosure Dimensions Drawing 400 Amp NEMA Type 1 and Type 3R ADV 5934 C...
Страница 34: ...26 Diagrams and Drawings TP 5660 11 98 Enclosure Dimensions Drawing 600 1200 Amp NEMA Type 12 ADV 5936B B...
Страница 35: ...TP 5660 11 98 Diagrams and Drawings 27 Enclosure Dimensions Drawing 1600 2000 Amp NEMA Type 1 ADV 5941 E...
Страница 38: ...30 Diagrams and Drawings TP 5660 11 98 Enclosure Dimensions Drawing 2500 3000 Amp NEMA Type 1 ADV 6242 B...
Страница 45: ...TP 5660 11 98 Diagrams and Drawings 37 Schematic Diagram S340 Logic 600 1200 Amp 321096 C...
Страница 46: ...38 Scheduled Maintenance TP 5660 11 98 Schematic Diagram S340 Logic 1600 3000 Amp 321097 A...
Страница 52: ...44 Scheduled Maintenance TP 5660 11 98 Schematic Diagram S340 Logic 400 Amp with Programmed Transition 321098 B...
Страница 54: ...46 Diagrams and Drawings TP 5660 11 98 Schematic Diagram M340 Logic 600 1200 Amp 321287 C...
Страница 55: ...TP 5660 11 98 Diagrams and Drawings 47 Schematic Diagram M340 Logic 1600 3000 Amp 321301 B...
Страница 61: ...TP 5660 11 98 Diagrams and Drawings 53 Schematic Diagram M340 Logic 400 Amp with Programmed Transition 321300 B...
Страница 70: ...TP 5660 11 98 62 Installation Notes...