7
1058907-W2-J
Temperatures
Optimum performance is obtained when
temperature differentials
of
20
°
C
or more
exist between blend and either supply. Blend control accuracy will begin to diminish
at temperature differentials below
10
°
C
.
Blend Temperature Range: between ambient cold and approximately 45
°
C,
according to hot water supply temperature.
Recommended Minimum Cold Water Supply Temperature: 5°C.
Recommended Maximum Hot Water Supply Temperature:
65
°
C.
Note!
The Thermotap-3 can accept temporary temperature excursions up to 85°C
without damage, however operation at such elevated supply temperatures is not
recommended. For reasons of general safety, hot water storage temperatures
should ideally be maintained at between 60 - 65°C where serving ablutionary
applications.
Connections
Hot and cold inlet supply connections are via 15 mm compression fittings or 1/2" BSP
male provided on the inlets to the isolating valves. Where flexible inlet tails are
chosen, the red hose is connected to the threaded hole on the tap marked with a
RED label adjacent to the hole (nearest to spout).
Flow Rate v Supply Pressure.