- 92 -
II
A_52
A_53
A_54
A_55
30.24 ÷ 30.26 mm
Components:
1
Dial indicator
2
Support for dial indicator
3
Sensor control gauge measurement: 30,24 ÷ 30,26 mm
4
Control master measurement: 30,24 ÷ 30,26 mm for sensor
gauge
If replacing the phase sensor, check the length of the sensor pin
using the tool in figure A_52.
Check by measuring the distance between magnetic end and the
sensor support surface (30,24 ÷ 30,26 mm).
The serial numbers of special tools are on page 103.
Disassembly / Reassembly
Sensor test
Remove the master
4
from the gauge
3
; insert the phase sensor and
check that the sensor falls within tolerance measurements of 30,015 ÷
30,035 mm.
See fig. A_53 -A_ 54.
Resetting the dial indicator
Assemble the dial indicator
1
onto support
2
.
Attach the support with the dial indicator to the gauge
3
.
Insert the master
4
into the gauge
3
and reset the dial indicator.