When the engines are not used for more than 3 months, they must be protected by the measures described
below:
STORAGE
External engine protection:
- Start the engine and heat it.
- Remove the drain plug and let the oil flow completely.
- Replace the oil filter with a new one (screw manually the new filter).
- Clean the oil drain plug and after having assembled a new gasket,
tighten it.
- Carry out the oil refilling to the upper level of the rod, using AGIP
RUSTIA C (for Countries in which this product is not available find an
equivalent product on the market).
- Start for about 10 minutes and verify any possible oil leakage, then
stop the engine.
External engine protection:
- Clean carefully cylinder cooling system fins and the blowing fan.
- Loosen the drive belt of the blowing fan.
- Protect the external non-painted surfaces with AGIP RUSTIA 100/F.
- Seal with adhesive tape the intake and exhaust systems
- Coat the engine with a nylon or plastic sheet.
- Keep in a dry place. If possible not in direct contact with the ground
and away from high voltage electric lines.
Injection systems protection:
- Empty the fuel tank.
- Replace the fuel filter with a new one.
- Carry out the filling of fuel using 10% of AGIP RUSTIA NT special
additives.
- After having performed the air bleeding, start the engine, verify any
possible fuel leakage, then stop the engine.
KD Workshop Manual_cod. ED0053029350_
1° ed
_ rev.
00
Содержание KD 626/3
Страница 1: ...KD 625 3 626 3 WORKSHOP MANUAL...
Страница 21: ...21 3 KD Workshop Manual_cod ED0053029350_1 ed_ rev 00...
Страница 69: ...69 NOTES KD Workshop Manual_cod ED0053029350_1 ed_ rev 00...
Страница 70: ...70 NOTES KD Workshop Manual_cod ED0053029350_1 ed_ rev 00...
Страница 99: ...99 NOTES KD Workshop Manual_cod ED0053029350_1 ed_ rev 00...