1st push

Motor Pump on / Heater on.

2nd push

Motor Pump on / Heater off.

3rd push

Motor Pump off / Heater off.

D. Air Bubble Volume Control

Turn the knob clockwise to increase air bubble volume and turn counterclockwise to decrease air bubble volume in 

whirlpool system.

Switch Function and Operation (Cont.)
C. Motor Pump/Heater  On/Off Control

Allows bather to switch off the heater when not required.

E. Auto Sanitising Cycle

Auto clean up cycle will commence 20 minutes after the bath has been emptied of water. The blower and heater 

 

will then restart and operate for 2 minutes sanitising the system with hot air before automatically shutting down.

F. Auto Timer

The auto safety timer will shut the air/spa system down automatically after 30 minutes of continual operation, 

 

and can be restarted again by pressing the electronic ON/OFF switch.

IMPORTANT : 

Air spa system will only operate for 5 seconds if insufficient water level is detected, automatically 

shutting down.

G. Leakage Detection

Leakage Detection indicator 

When the fixture is powered on and the bath has run out of water, 

 

press  Blower Speed Decrease button, Blower Speed Increase button and 

 

Motor/Pump-Heater button simultaneously for more than 3 seconds to 

create a simulation of electricity leakage, then the indicator will flash in 

red and green alternatively. This indicates the leakage detection function  

is  well  in  use,  otherwise,  there’s  possibility  that  this  function  fails  to 

 

operate normally and may result in electric shock accident. 

Release three buttons and the bath will not function anymore if any key 

 

is pressed. Make the bath powered-on again and the bath will restore its 

function.

Power

Water

Fault

Indicator flashes in red 

and green alternatively.

Indicator lights in red

Indicator lights in blue

Indicator turns off

Turn counterclockwise to decrease 

air bubble volume in whrilpool

Turn clockwise to increase 

 air bubble volume in whirlpool

1241693-X2-B 10 

 Kohler  Co.

Содержание K-97260X

Страница 1: ...Installation and Care Guide Dual System Bath 1241693 X2 A 2018 Kohler Co K 97260X...

Страница 2: ...al before you start installation If you encounter any installation or performance problems please call 0 2204 6222 for Call Center Thailand Thank you again for choosing Kohler Company Important Inform...

Страница 3: ...ing Specifications If using a rim mounted bath faucet flexible connections between the valves and spout may be required Confirm adequate mounting connection space of specified faucet for your installa...

Страница 4: ...d level This bath may be installed next to the wall or in an island installation An island installation requires a four side surround In both instances make sure the deck is supported by brick or conc...

Страница 5: ...and resting on all support blocks Install the drain to the bath according to the drain manufacturer s instructions Do not connect the trap at this time To adjust the height loosen the nut A adjust th...

Страница 6: ...t carrying conductor Follow local electrical codes Bond in accordance with national and local codes N N E L L E Control Box Power Supply LINE LOAD OFF ON 2 P 20 A 120 240V 50 60 Hz SENSITIVITY 15 mA O...

Страница 7: ...it will be required NOTE Hose connection to manifold is factory fitted Push the rubber cuff onto blower nozzle and secure in position with hose clip Connect the blower to the control box Hose Clip Con...

Страница 8: ...he flow Press the Power On Off button a second time to turn the bath off NOTE The water temperature in the bath should not exceed 40 C 104 F The heater will automatically turn off as the water tempera...

Страница 9: ...ater ensuring that the water level 40mm above spa jets After you press Motor pump heater on off the water level indicator will light in green Fill the bath with warm water ensuring that the water leve...

Страница 10: ...y operate for 5 seconds if insufficient water level is detected automatically shutting down G Leakage Detection Leakage Detection indicator When the fixture is powered on and the bath has run out of w...

Страница 11: ...ck wire connections If necessary replace user keypad B User keypad does not work B Replace user keypad C Pump does not work C Replace pump D Controller does not work D Replace the controller Troublesh...

Страница 12: ...0 2204 6222 Earth Ground ELCB 1241693 X2 B 12 Kohler Co...

Страница 13: ...ELCB 220 240 20 50 60 50x 45 Kohler Co 13 1241693 X2 B...

Страница 14: ...390 15 0 4 2 5 4 2 1 2 300 400 2 1500 500 700 Brick 2 1241693 X2 B 14 Kohler Co...

Страница 15: ...A B A 560 600 A B A B Kohler Co 15 1241693 X2 B...

Страница 16: ...20 50 60 ELCB 15 ELCB Class 1 GB 4706 1 2005 N N E L L E LINE LOAD OFF ON 2 P 20 A 120 240V 50 60 Hz SENSITIVITY 15 mA OPERATING TIME MAX 0 1s TEST BUTTON LEAKAGE INDICATOR INPUT OUTPUT 1241693 X2 B...

Страница 17: ...1 5 1 5 Kohler Co 17 1241693 X2 B...

Страница 18: ...40 40 C 104 F 40 C 104 F 40 1241693 X2 B 18 Kohler Co...

Страница 19: ...40 Power Water Fault ON OFF AUTO SANITISING CYCLE OSCILLATING CYCLE PRESS BOTH Power Water Fault Power Water Fault 40 ON OFF ON OFF Kohler Co 19 1241693 X2 B...

Страница 20: ...1 2 3 20 2 30 5 3 3 Power Water Fault 1241693 X2 B 20 Kohler Co...

Страница 21: ...1 ELCB 2 30 ELCB ELCB 3 30 4 5 6 Kohler Co 21 1241693 X2 B...

Страница 22: ...1241693 X2 B Kohler Co...

Страница 23: ...Kohler Co 1241693 X2 B...

Страница 24: ...ILAND PUBLIC COMPANY LIMITED 16th FL JasmineCityBldg 2 Soi Sukhumvit23 Sukhumvit Road Wattana Bangkok Thailand 10110 Call Center Tel 66 2204 6222 Fax 66 22046224 ASIA CUSTOMER SERVICE CENTRE No 158 Ji...

Отзывы: