9. Install the Tower Face and Handspray
Install the Tower Face
Close the shower valve by rotating the uppermost valve counterclockwise.
Turn on the water supply to the tower and check for leaks. Do not open the shower valve at this
time.
Check the sealant around the water supply lines. Fill any gaps as needed.
Position the tower face onto the tower.
Starting at the bottom and alternating side-to-side, use the sockethead screws to secure the tower
face to the tower.
Install the Handspray
Apply thread sealant to the male adapter.
Thread the handspray hose to the adapter and securely wrench tighten.
Handspray
Hose
Apply thread
sealant.
Tower Face
Screws
Tower Face
Male Adapter
#6-32 x 1/2"
Sockethead Screw
Kohler Co.
11
1010418-2-C