Optional Temperature Limiting Adjustment
CAUTION: Risk of personal injury.
Do not set the water
temperature above 120°F (49°C). Setting the water
temperature at or below this temperature will minimize the
risk associated with scalding hazards.
Turn the valve clockwise to the full open position and let the hot
water run for several minutes. Position a thermometer in the
water stream and check the temperature.
For
minor water temperature changes,
adjust the setscrew, and
recheck the water temperature.
For
major water temperature changes,
remove the O-ring and
collar from the valve stem. Slowly rotate the valve stem until the
desired water temperature is reached.
Reinstall the collar on the valve stem with the setscrew against
the side of the tab.
Reinstall the O-ring, rotate the valve stem counterclockwise to
shut the water off, and recheck the water temperature.
NOTE:
After adjustment, complete the required information on the
valve label.
Lifetime Limited Warranty
Kohler Co. warrants its faucets manufactured after January 1, 1997, to
be leak and drip free during normal residential use for as long as the
original consumer purchaser owns his/her home. *If the faucet should
Setscrew
Tab
Valve Stem
Collar
Valve Label
O-Ring
Tab
Collar
Setscrew
HiFlow Valve
All Other Valves
Kohler Co.