SYMPTOMS
A. Turn on pump.
B. Check for loose connections or wires
leading from backjet pulse canister to
control. Replace backjet pulse canister or
control if necessary.
C. Fill whirlpool so water level sensors are
covered.
D. Replace actuator switch.
E. Check for loose connections or wires
leading from the pump motor to the control.
F. Remove blockage.
G. Reconnect or replace switch wires that
use modular plug.
PROBABLE CAUSES
15.Backjets do not
operate.
A. Whirlpool pump is not operating.
B. Backjet butterfly valve does not open.
C. Not enough water in whirlpool.
D. Actuator switch does not work.
E. Power from pump motor to control is off.
F. Backjet pipe is blocked.
G. Switch wire from switch to control is
disconnected.
A. Check for loose connections or wires
leading from pulse canister to control.
Replace pulse canister or control if
necessary.
B. Replace switch.
C. Reconnect or replace switch wires that
use modular plug.
16.Backjets do not
pulse.
A. Pulse canister does not work.
B. Switch does not work.
C. Switch wire from switch to control is
disconnected.
Troubleshooting the Beckjet Syetem
A.
B.
C.
D.
E.
F.
G.
15.
A.
B.
C.
D.
E.
F.
G.
A.
B.
C.
16.
A.
B.
C.
18
RECOMMENDED ACTION
1141609-T01-A