4 — PROGRAMMABLE PARAMETERS
Curtis Model 3401T – August 2022
pg. 32
SET HOURMETERS MENU
Use the Set Hourmeters menu to specify the password for resetting hour meters. After the password
has been entered the
is displayed. The submenu contains parameters that
reset the hour meters.
Note: The default password for resetting hour meters is 12345. Curtis recommends that you change
the default password.
Take the following steps to specify the password:
1. Specify the password as the Input Hrm Password parameter value.
2. Set the Confirm Input Password parameter to On. If the password is valid, the Set Hourmeters
submenu is displayed.
SET HOURMETERS MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES
DATA SIZE
ACCESS LEVEL
DEFAULT VALUE
DESCRIPTION
Input Hrm Password
0x6906:00
11111–99999
11111–99999
32-bit
OEM Dealer
55555
Specifies the password for resetting hour meters.
Note
: The default value is not the same value as the
actual password.
Confirm Input Password
0x6908:00
Off/On
0–1
32-bit
OEM Dealer
Off
Submits the password specified with the Input Hrm
Password parameter.
Status of Set Hourmeters
0x6907:00
Enumerated
0–1
32-bit
OEM Dealer
Disable
Indicates whether the hour meters can be reset:
0 = Disable
1 = Enable
When a valid hour meter password has been
specified, the value changes to Enable.
RO
Set Hourmeters Submenu
Use the Set Hourmeters submenu to reset hour meters and change the password for resetting them.
SET HOURMETERS SUBMENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES
DATA SIZE
ACCESS LEVEL
DEFAULT VALUE
DESCRIPTION
Reset KSI Hourmeter
0x646A:00
Off/On
0–1
16-bit
OEM Dealer
Off
Resets the keyswitch hour meter.
Reset TRA Hourmeter
0x646B:00
Off/On
0–1
16-bit
OEM Dealer
Off
Resets the traction controller hour meter.
Reset HYD Hourmeter
0x646C:00
Off/On
0–1
16-bit
OEM Dealer
Off
Resets the pump controller hour meter.
Set KSI Hourmeter
0x642C:00
0–99999.9 hours
0–999999
32-bit
OEM Dealer
0
Sets the time indicated by the keyswitch hour meter.
Change Hrm Password
0x6905:00
11111–99999
11111–99999
32-bit
OEM Dealer
12345
The password for resetting the hour meters.