4 — PROGRAMMABLE PARAMETERS
pg. 31
Curtis Model 3401T – August 2022
MAIN MENU PARAMETERS
The 3401T’s main menu contains the following parameters:
MAIN MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES
DATA SIZE
ACCESS LEVEL
DEFAULT VALUE
DESCRIPTION
Model Number
0x600D:00
–32768 to 32767
–32768 to 32767
32-bit
Field Basic
0
Indicates the model number.
RO
Serial Number
0x1018:04
0–999999
0–999999
32-bit
Field Basic
0
Indicates the serial number.
RO
CDEV
0x690D:00
–2147483648 to
2147483647
–2147483648 to
2147483647
32-bit
Field Basic
0
Indicates the device profile’s version.
RO
OS Version
0x690C:00
–2147483648 to
2147483647
–2147483648 to
2147483647
32-bit
Field Basic
0
Indicates the operating system’s version.
RO
LCD Backlight
0x640F:00
1–10
1–10
32-bit
Field Basic
7
Indicates the brightness of the device’s backlight,
with 10 indicating the maximum brightness.
Speed Unit
0x6040:00
Enumerated
0–1
32-bit
Field Basic
0
Indicates the speedometer’s unit of measurement:
0 = KPH
1 = MPH
Language
0x4802:00
Enumerated
0–2
32-bit
Field Basic
0
Indicates the language in which the 3401T displays
information. Values other than 0–2 are reserved:
0 = English
1 = Chinese
2 = Korean
3 = Japanese
4 = French
5 = German
6 = Italian
7 = Spanish
8 = Portuguese
9 = Swedish
Battery Type
0x690B:00
Enumerated
0–1
32-bit
Field Basic
0
Indicates the battery type:
0 = Lead-Acid
1 = Lithium