TP-7045 3/18c
21
Section 4 Exhaust System
Note:
Read the text for complete explanation
of dimensions and other installation
considerations.
Note:
Use two hose clamps on each end of
all flexible exhaust hose connections.
Note:
Data applies to both rear- and
side-exhaust installations.
Note:
Damage caused by water ingestion will
not be covered by the generator
warranty.
Waterline
7
13
12
11
14
10
9
8
18
19
6
16
4
5
21
15
22
1. Cap
2. Reed valve
3. Mounting base
4. Maximum silencer vertical lift of 1.2 m (4 ft.)
5. Exhaust mixer elbow distance above waterline; if less than
23 cm (9 in.), a siphon break is required
6. Minimum siphon break distance above waterline of 30.5 cm
(1 ft.)
7. Siphon break
8. Exhaust mixer elbow
9. Heat exchanger (locations vary by model)
10. Coolant recovery tank (located on the unit on some models)
11. Seawater strainer
12. Seacock
13. Intake strainer
14. Engine-driven seawater pump
15. Minimum exhaust hose pitch of 1.3 cm per 30.5 cm (0.5 in. per ft.)
16. Maximum distance between silencer and exhaust mixer elbow
of 3 m (10 ft.)
17. Maximum distance between silencer and exhaust outlet of
1.5 m (5 ft.)
18. Silencer (customer-supplied)
19. Minimum exhaust hose pitch of 1.3 cm per 30.5 cm
(0.5 in. per ft.)
20. Maximum distance between exhaust outlet and generator of
4.6 m (15 ft.)
21. Minimum exhaust outlet distance above waterline of 10 cm
(4 in.)
22. Exhaust hose (exhaust gas outlet hose after separator)
23. Gas/water separator (optional). Install directly above the
canister muffler.
24. Distance above waterline for drain outlet from silencer must be
equal to or greater than water drain (item 17) to be greater
than 30.5 cm (1 ft.)
25. Water drain distance below waterline
26. Water drain (separated water from item 23)
27. System installer is responsible for designing enough capacity
into the lift muffler and plumbing to prevent engine water
ingestion upon shutdown. Otherwise, water will drain back
into item 18 on generator set shutdown.
20
23
2
1
3
17
24
25
27
26
Figure 4-6
Typical Mid- and Below-Waterline Installation with Optional Gas/Water Separator
Содержание 12EFKOZD
Страница 2: ...TP 7045 3 18c 2...
Страница 8: ...TP 7045 3 18c 8 Safety Precautions and Instructions Notes...
Страница 12: ...TP 7045 3 18c 12 Section 2 Location Lifting and Mounting Notes...
Страница 24: ...TP 7045 3 18c 24 Section 4 Exhaust System Notes...
Страница 28: ...TP 7045 3 18c 28 Section 5 Fuel System Notes...
Страница 34: ...TP 7045 3 18c 34 Section 6 Electrical System Notes...
Страница 50: ...TP 7045 3 18c 50 Section 7 Installation Drawings Notes...
Страница 54: ...TP 7045 3 18c 54 Section 8 Reconnection Figure 8 3 Generator Reconnection ADV 5875F U...
Страница 81: ...TP 7045 3 18c 81...
Страница 82: ...TP 7045 3 18c 82...
Страница 83: ...TP 7045 3 18c 83...