TP-7045 3/18c
10 Section 1 Introduction
Note:
See text for complete explanation of installation
requirements.
Note:
Use two hose clamps on each end of all flexible
exhaust hose connections.
1.2 Decision-Maker
r
3500
Controller Information
The following data must be resident for the controller to
function.
D
Application program
contains the software that
controls system operation. The application file was
preprogrammed in the
original
controller at the
factory.
D
Personality profile
is specific to the engine and
alternator and was preprogrammed in the
original
controller at the factory.
A backup disk of the personality profile and
application program is supplied with the literature
packet shipped with the generator set. Typically, the
Kohler authorized distributor/dealer passes this disk
onto the owner. Inform the owner to store this disk for
possible future use such as controller replacement or
other circumstances requiring a backup.
Note:
If the personality disk is NOT available, request
a replacement from Kohler Co. using the
generator set serial number or order number.
D
User parameters
unique to an installation include
timer values, setpoints, generator set data such as
voltage and input/output selections.
These
parameters are typically set up for or by the installer at
the time of installation. User parameters are typically
recorded on the personality profile disk, a separate
backup disk/drive, or written on a paper form
.
Note:
If the user parameters are included on the
personality disk, the disk label should indicate
Site Program—Yes.
Note:
After the unit is set up on the vessel, Kohler
authorized distributor/dealer saves any user
parameter changes to an external medium.
The installer or a Kohler authorized
distributor/dealer passes this information onto
the owner. Inform the owner to store this
information for possible future use such as
controller replacement or other circumstances
requiring a backup.
Note:
Controller service replacement kits do not
include the three files. The service technician
must
install the three files into the replacement
controller.
Содержание 12EFKOZD
Страница 2: ...TP 7045 3 18c 2...
Страница 8: ...TP 7045 3 18c 8 Safety Precautions and Instructions Notes...
Страница 12: ...TP 7045 3 18c 12 Section 2 Location Lifting and Mounting Notes...
Страница 24: ...TP 7045 3 18c 24 Section 4 Exhaust System Notes...
Страница 28: ...TP 7045 3 18c 28 Section 5 Fuel System Notes...
Страница 34: ...TP 7045 3 18c 34 Section 6 Electrical System Notes...
Страница 50: ...TP 7045 3 18c 50 Section 7 Installation Drawings Notes...
Страница 54: ...TP 7045 3 18c 54 Section 8 Reconnection Figure 8 3 Generator Reconnection ADV 5875F U...
Страница 81: ...TP 7045 3 18c 81...
Страница 82: ...TP 7045 3 18c 82...
Страница 83: ...TP 7045 3 18c 83...