2.4 Advanced Digital Control
Operation
Figure 2-2 illustrates the user interface on the Advanced
Digital Control (ADC 2100).
Note:
Have setup and adjustments of the ADC 2100
performed
only
by
an
authorized
Kohler
distributor/dealer.
The setup and adjustments
are password protected.
GM28707A-C
1. LED display
2. Up and down arrow buttons (use for setup and adjustment
only)
3. Generator set master switch
4. Select button (use for setup and adjustment only)
1
4
3
2
Figure 2-2
ADC 2100 Control
2.4.1
Controls and Indicators
Figure 2-3 describes the controls and indicators located
on the controller. The LED display indicates generator set
status as shown in Figure 2-3. The display is active when
the master switch is in the RUN or AUTO position and
remains active until the generator set master switch is
moved to the OFF/RESET position or the power to the
controller is removed. If the factory-installed continuous
power mode jumper has been disconnected, the LED
display turns off 48 hours after the generator set
shutdown. See Section 2.4.6.
The buttons on the controller keypad are used only for
system configuration and adjustment. The controller is
factory-set and should not require configuration or
adjustment under normal operating conditions. If the
generator set is reconnected to a different voltage
and/or frequency, refer to an authorized Kohler
distributor/dealer
for
system
configuration
and
adjustment instructions.
Control or Indicator
Item
Description
LED display
Runtime hours
Displays total generator set runtime hours.
p y
Crank indication
Displays CC_1, CC_2, or CC_3 to indicate the first, second or third attempt to start the
engine. The last digit flashes during the crank cycle rest periods.
Fault codes
Flashes a 2- or 3-letter fault code to indicate various fault conditions. See Section 2.4.4.
Software version
See TP-6335, Generator Set Installation Manual.
Keypad
Select and arrow
buttons
The keypad is used for controller setup and adjustment only. Have setup and adjustments
performed only by an authorized distributor/dealer. The setup and adjustment functions are
password-protected.
Generator set master
switch
Three-position
switch
Switch functions as the generator set operation and controller reset switch.
Figure 2-3
ADC 2100 Controls and Indicators
Содержание 10ERG
Страница 1: ...Commercial Mobile Generator Sets Model 10ERG 13ERG 15ERG TP 6334 9 04 Operation...
Страница 4: ......
Страница 10: ...VI Safety Precautions and Instructions TP 6334 9 04 Notes...
Страница 14: ...TP 6334 9 04 2 Service Views Notes...
Страница 20: ...8 Operation TP 6334 9 04 Notes...
Страница 38: ...TP 6334 9 04 26 Section 5 Wiring Diagrams GM28747A C Figure 5 1 Wiring Diagram Sheet 1 of 2...
Страница 39: ...TP 6334 9 04 27 Section 5 Wiring Diagrams GM28747B C Figure 5 2 Wiring Diagram Sheet 2 of 2...
Страница 40: ...TP 6334 9 04 28 Section 5 Wiring Diagrams ADV6846A A Figure 5 3 Schematic Diagram Sheet 1 of 2...
Страница 41: ...TP 6334 9 04 29 Section 5 Wiring Diagrams ADV6846B A Figure 5 4 Schematic Diagram Sheet 2 of 2...
Страница 42: ...TP 6334 9 04 30 Section 5 Wiring Diagrams GM33846 A Figure 5 5 Accessory Wiring Diagram...
Страница 46: ......