Install the Suction Assembly (cont.)
CHECK POINT # 4.
Confirm that:
The heater is assembled to the
pump.
The suction bracket assembly
is positioned at least 12” (30.5
cm) away from the heater.
Rigid 1–1/2” I.D. PVC tubing
is measured, cut and fit, but
not solvent welded.
The waterline height
confirmed using the label on
the pump box.
There is a minimum 1/4” (6
mm) per foot (30.5 cm) pitch
from the pump inlet to the
suction housing.
The tower mounting frame is
permanently secured.
7. Solvent Weld Tubing
NOTE:
The product model number is printed on a label on the pump side of the overflowing bath. This
label also identifies the electrical rating of the product. All whirlpools come equipped with a wiring
junction box and are designed to operate between 208 VAC and 240 VAC at either 50 HZ or 60 Hz.
WARNING: Risk of electrical shock.
Make sure the power has been disconnected before performing
the following procedures. Refer to the “Important Information” section.
WARNING: Risk of electrical shock.
To reduce the risk of electrical shock, connect the pump to a
properly grounded Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage Circuit-Breaker (ELCB).
This will provide additional protection against line-to-ground shock hazard. A 208-240 V, 20 A, 50/60
Hz dedicated circuit is required.
IMPORTANT!
The load neutral is not used. There should be no connection to the load neutral terminal
on the Ground-Fault Circuit-Interrupter (GFCI) breaker. The green wire with the yellow stripe is the
equipment ground
and needs to be connected to the neutral bus in the main circuit breaker box.
The overflowing bath control and system have been pre-wired at the factory. A licensed electrician
should make a routine service connection to the junction box.
Connect service to the junction box. The junction box contains blue, brown, and green with a yellow
stripe colored wires.
Follow local electrical codes. Bond in accordance with national and local codes.
A wiring harness has been pre-wired at the factory, allowing communication between the keypad,
all features, and the control. No additional wiring is required, but ensure that all wires are securely
fastened.