Within the guarantee period we will resolve defects in 

materials or workmanship, free of charge, by repairing or 

replacing parts or product as we may choose.

This guarantee is in addition to your statutory rights 

and is subject to the following conditions:

  ●  The guarantee applies solely to the original installation  

    under normal use and to the original purchaser only.

    The  product  must  be  installed  and  maintained  in 

    accordance with the instructions given in this user 

    guide.

  ●  Servicing  must  only  be  undertaken  by  us  or  our   

    appointed  representative. 

Note!

  if  a  service  visit   

    is  required  the  product  must  be  fully  installed  and  

    connected to services.

  ●  Repair under this guarantee does not extend the original

    expiry  date. The  guarantee  on  any  replacement   

    parts or product ends at the original expiry date.

  ●  For shower fi ttings or consumable items we reserve

    the right to supply replacement parts only.

The guarantee does not cover:

  ●  Call  out  charges  for  non  product  faults  (such  as 

damage or performance issues arising from incorrect 

installation,  improper use, inappropriate cleaning, 

lack  of  maintenance,  build  up  of  limescale,  frost 

damage, corrosion, system debris or blocked fi lters) 

or where no fault has been found with the product.

  ●  Water or electrical supply, waste and isolation issues.

  ●  Compensation  for  loss  of  use  of  the  product  or 

consequential loss of any kind.

  ●  Damage or defects caused if the product is repaired 

or modifi ed by persons not authorised by us or our 

appointed representative.

  ●  Routine  maintenance  or  replacement  parts  to 

comply with the requirements of the TMV 2 or TMV 

3 healthcare schemes.

  ●  Accidental or wilful damage.

  ●  Products purchased ex-showroom display.

What to do if something goes wrong

If  your  product  does  not  work  correctly  refer  to  this 

manual for fault diagnosis and check that it is installed 

and commissioned in accordance with our instructions.

If this does not resolve the issue, contact us for help 

and advice.

Extended Guarantees

A selection of protection plans are available that 

enable you to cover repair bills (excludes Eire). Ring 

01922 471763 for more details.

01 531 9337

Mira Customer Services Dept, Cromwell 

Road, Cheltenham, Gloucestershire, GL52 

5EP

Helpdesk  Service

  -  Ring  our  Customer 

Services Team for product advice, to purchase 

spare parts or accessories or to set up service 

visit. You can contact us via phone or e-mail, 

details  below.  Please  provide  your  model 

name,  power  rating  (if  applicable)  and  date 
of purchase.

Mira Showers Website (www.mirashowers.

co.uk)

Visit  our  website  to  register  your  guarantee, 

download  user  guides,  diagnose  faults, 

purchase  our  full  range  of  accessories  and 
popular spares, or request a service visit.

Spares and Accessories

 - We hold the largest 

stocks of genuine Mira spares and accessories. 

Contact us for a price or visit our website to 

purchase items from our accessory range and 
popular spares

Service/Repairs -

 No one knows our products 

better  than  our  nationwide  team  of  Service 

Technicians. We can carry out service or repair 

work to your product both during and after the 

guarantee  period. Ask  about  our  fi xed  price 

service repairs.

To Contact Us: UK

CUSTOMER SERVICE

E-mail: Visit 

www.mirashowers.co.uk/

contactus

To Contact Us: Eire Only

0844 571 5000

Fax: 01242 282595

E-mail: CustomerServiceEire@

mirashowers.com

Содержание Mira Sprint

Страница 1: ...1 Stop Start Mira Sprint 8 5 9 5 kW These instructions must be left with the user Installation and User Guide For SPARES ADVICE or REPAIRS Please call us on 0844 571 5000 UK Only...

Страница 2: ...trols for power selection and for temperature flow adjustment A unique flow regulator stabilises any temperature changes caused by water pressure fluctuations which can result from taps being turned o...

Страница 3: ...is properly insulated 5 DO NOT switch the shower on if there is a possibility that the water in the shower is frozen 6 DO NOT switch the shower on if water starts leaking from the shower case Isolate...

Страница 4: ...boxes to familiarise yourself with the part names and to confirm that the parts are included 1 x Mira Sprint Electric Shower 3 x Wall Plugs 3 x Fixing Screws 1 x Installation and User Guide 1 x Guara...

Страница 5: ...108 EC EMC Directive The Mira Sprint range of showers are high power appliances and are subject to conditional connection If the main electrical supply fuse is rated less than 80 Amps the local elect...

Страница 6: ...CaCO3 Outlet Connection 1 2 BSP Male Electrical Variant Sprint 8 5 Sprint 9 5 Nominal Power at 230 V ac 7 8 kW 8 7 kW Nominal Power at 240 V ac 8 5 kW 9 5 kW Recommended MCB Rating 40 A 40 A Maximum S...

Страница 7: ...on within the shower area and is fitted with a pressure relief valve It must be positioned over a water catchment area with the controls at a convenient height for the user 6 The shower must be fitted...

Страница 8: ...ctions caused by excessive limescale formation are not covered by this shower s guarantee see back page for details 18 The installation must not cause the hose to be sharply kinked during normal use D...

Страница 9: ...m A separate supply must be provided from the consumer unit to the shower 5 DO NOT supply any other electrical equipment including extractor fans or pumps via this product 6 This shower must be provid...

Страница 10: ...let the connection to the inlet connector must still be made from the top or bottom through a bend Warning To avoid damage to the case when soldered fittings are used pre solder the pipework and fitti...

Страница 11: ...Caution DO NOT twist the individual cable cores of the live and neutral conductors as this will prevent them from entering the terminal block 15 Fit an earth sleeve to the earth conductor Connect the...

Страница 12: ...Cover Retaining Screws Do not fit the Mira Sprint to the wall and tile up to the case The Mira Sprint must be fitted on to a finished flat and even wall surface small pillars on the back of the case...

Страница 13: ...ing from the bottom of the case 4 Turn the top control knob to the LOW position 5 Switch on the electrical supply at the double pole switch The power neon will provide a visual indication that the ele...

Страница 14: ...this shows that the full power setting is operating correctly 10 Set the shower temperature by rotating the bottom knob as necessary Turn the knob clockwise for hotter water and anticlockwise for cool...

Страница 15: ...all electrical appliances 8 DO NOT connect the outlet of the shower to any tap control valve trigger handset or showerhead other than those specified for use with this shower Only Kohler Mira recommen...

Страница 16: ...er with less flow Anticlockwise rotation will give cooler water with more flow 6 To turn off the Mira Sprint press the stop button The appliance will continue to run for a few seconds before stopping...

Страница 17: ...ing the thermal trip to operate and cut the power to the heater tank Showerhead sprayplate blocked Other outlets being used whilst showering causing water pressure to drop below minimum required to op...

Страница 18: ...he cover of the appliance Only a competent tradesperson should remove the cover Key light illuminated A POWER indicator B LOW FLOW indicator Malfunction A B Cause Remedy No water or very low flow rate...

Страница 19: ...switch is incorporated that cuts the power to the heater tank at too high a temperature Showerhead spray plate blocked Turn the temperature knob sufficiently anticlockwise to increase the water flow a...

Страница 20: ...hority undertaker Check water supply static pressure Note Static pressure may fall below 0 2 bar when other appliances are operated e g dishwasher washing machine etc Power neon goes off when unit is...

Страница 21: ...aning Many household cleaners contain abrasives and chemical substances and should not be used for cleaning plated or plastic fittings These finishes should be cleaned with a mild washing up detergent...

Страница 22: ...off inlet water supply 1 Remove the three cover retaining screws the cover and the service tunnel 2 Remove the screws that hold the inlet clamp bracket in position and remove the clamp bracket 3 Loos...

Страница 23: ...6 025 Service Tunnel 1563 527 Terminal Block A A B B B B B 1563 509 Switching Assembly 872 01 Microswitch N O 2 pin 1563 514 Low Flow Neon Assy 1563 515 Power On Neon Assy B 1563 516 Outlet Connector...

Страница 24: ...product or consequential loss of any kind Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed representative Routine maintenance or replac...

Отзывы: