![Kohler Mira Mira Sprint Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/kohler-mira/mira-sprint/mira-sprint_installation-and-user-manual_1990218022.webp)
22
Inlet Connector
Clamp Bracket
Inlet Filter
'O' Seal
SERVICING
WARNING
There are no user serviceable parts inside the shower.
Servicing of the shower must only be carried out by qualified, competent
personnel following the instructions provided in this guide and those provided
with any spare part.
Before replacing any parts, ensure that the underlying cause of the malfunction
has been resolved.
Inlet Filter
Warning!
Make sure that the electrical supply is turned off at the mains and the
appropriate circuit fuse is removed. Turn off inlet water supply.
1.
Remove the three cover retaining screws, the cover and the service tunnel.
2.
Remove the screws that hold the inlet clamp bracket in position and remove
the clamp bracket.
3.
Loosen the screws that hold the flow valve and switch assembly and the heater
tank in position.
4.
Carefully pull the flow valve and switch assembly and the heater tank away
from the case. Make sure that you ease the inlet connector off the inlet supply
pipe.
5.
Remove the inlet connector complete with 'O' seal. Use a suitable tool to
withdraw the inlet filter. Clean or renew the inlet filter.
6.
Refit the inlet filter, make sure that the inlet filter is correctly orientated and
pushed fully home.
7.