Installer Fault Diagnosis
Read the section
'Important Safety Information'
first.
Providing the shower has been correctly installed and is operated in accordance
with the instructions contained in this guide, difficulties should not arise. If any
maintenance is required then it must be carried out by a competent tradesperson for
whom the fault diagnosis chart and maintenance instructions are provided. Before
replacing any parts ensure that the underlying cause of the malfunction has been
identified.
Warning!
There are no user serviceable components beneath the cover of the
appliance. Only a competent tradesperson should remove the cover.
Key
-
=
light illuminated
A = 'POWER'
indicator
B = 'LOW FLOW'
indicator
Malfunction
A B
Cause
Remedy
No water or very low
flow rate.
Showerhead spray plate blocked.
Incoming water supply stop
valves or appliance isolating
valve turned down or off.
Hose or showerhead blocked.
Insufficient water supply
pressure.
Heater tank excessively scaled.
Flow valve faulty.
Inlet strainer blocked.
Remove & clean (refer to section:
'Maintenance'
in your shower
fittings installation and user
guide).
Turn fully on.
Clear blockage or renew hose or
showerhead.
Contact your local water
authority/undertaker.
Renew the heater tank.
Renew the flow valve.
Remove and clean, refer to
section:
'Maintenance, Inlet
strainer cleaning'
.