Installer Fault Diagnosis

Read the section 

'Important Safety Information'

 first.

Providing the shower has been correctly installed and is operated in accordance 

with  the  instructions  contained  in  this  guide,  difficulties  should  not  arise.  If  any 

maintenance is required then it must be carried out by a competent tradesperson for 

whom the fault diagnosis chart and maintenance instructions are provided. Before 

replacing any parts ensure that the underlying cause of the malfunction has been 

identified.

Warning!

 There are no user serviceable components beneath the cover of the 

appliance. Only a competent tradesperson should remove the cover.

Key

 -   

 =

 light illuminated

A = 'POWER'

 indicator

B = 'LOW FLOW'

 indicator

Malfunction

A B

Cause

Remedy

No water or very low 

flow rate.

Showerhead spray plate blocked.

Incoming water supply stop 

valves or appliance isolating 

valve turned down or off.

Hose or showerhead blocked.

Insufficient water supply 

pressure.

Heater tank excessively scaled.

Flow valve faulty.

Inlet strainer blocked.

Remove & clean (refer to section: 

'Maintenance'

 in your shower 

fittings installation and user 

guide).

Turn fully on.

Clear blockage or renew hose or 

showerhead.

Contact your local water 

authority/undertaker.

Renew the heater tank.

Renew the flow valve.

Remove and clean, refer to 

section: 

'Maintenance, Inlet 

strainer cleaning'

.

Содержание Mira Sprint

Страница 1: ...1 Stop Start Mira Sprint 8 5 9 5 kW These instructions must be left with the user Installation and User Guide For SPARES ADVICE or REPAIRS Please call us on 0844 571 5000 UK Only...

Страница 2: ...trols for power selection and for temperature flow adjustment A unique flow regulator stabilises any temperature changes caused by water pressure fluctuations which can result from taps being turned o...

Страница 3: ...is properly insulated 5 DO NOT switch the shower on if there is a possibility that the water in the shower is frozen 6 DO NOT switch the shower on if water starts leaking from the shower case Isolate...

Страница 4: ...boxes to familiarise yourself with the part names and to confirm that the parts are included 1 x Mira Sprint Electric Shower 3 x Wall Plugs 3 x Fixing Screws 1 x Installation and User Guide 1 x Guara...

Страница 5: ...108 EC EMC Directive The Mira Sprint range of showers are high power appliances and are subject to conditional connection If the main electrical supply fuse is rated less than 80 Amps the local elect...

Страница 6: ...CaCO3 Outlet Connection 1 2 BSP Male Electrical Variant Sprint 8 5 Sprint 9 5 Nominal Power at 230 V ac 7 8 kW 8 7 kW Nominal Power at 240 V ac 8 5 kW 9 5 kW Recommended MCB Rating 40 A 40 A Maximum S...

Страница 7: ...on within the shower area and is fitted with a pressure relief valve It must be positioned over a water catchment area with the controls at a convenient height for the user 6 The shower must be fitted...

Страница 8: ...ctions caused by excessive limescale formation are not covered by this shower s guarantee see back page for details 18 The installation must not cause the hose to be sharply kinked during normal use D...

Страница 9: ...m A separate supply must be provided from the consumer unit to the shower 5 DO NOT supply any other electrical equipment including extractor fans or pumps via this product 6 This shower must be provid...

Страница 10: ...let the connection to the inlet connector must still be made from the top or bottom through a bend Warning To avoid damage to the case when soldered fittings are used pre solder the pipework and fitti...

Страница 11: ...Caution DO NOT twist the individual cable cores of the live and neutral conductors as this will prevent them from entering the terminal block 15 Fit an earth sleeve to the earth conductor Connect the...

Страница 12: ...Cover Retaining Screws Do not fit the Mira Sprint to the wall and tile up to the case The Mira Sprint must be fitted on to a finished flat and even wall surface small pillars on the back of the case...

Страница 13: ...ing from the bottom of the case 4 Turn the top control knob to the LOW position 5 Switch on the electrical supply at the double pole switch The power neon will provide a visual indication that the ele...

Страница 14: ...this shows that the full power setting is operating correctly 10 Set the shower temperature by rotating the bottom knob as necessary Turn the knob clockwise for hotter water and anticlockwise for cool...

Страница 15: ...all electrical appliances 8 DO NOT connect the outlet of the shower to any tap control valve trigger handset or showerhead other than those specified for use with this shower Only Kohler Mira recommen...

Страница 16: ...er with less flow Anticlockwise rotation will give cooler water with more flow 6 To turn off the Mira Sprint press the stop button The appliance will continue to run for a few seconds before stopping...

Страница 17: ...ing the thermal trip to operate and cut the power to the heater tank Showerhead sprayplate blocked Other outlets being used whilst showering causing water pressure to drop below minimum required to op...

Страница 18: ...he cover of the appliance Only a competent tradesperson should remove the cover Key light illuminated A POWER indicator B LOW FLOW indicator Malfunction A B Cause Remedy No water or very low flow rate...

Страница 19: ...switch is incorporated that cuts the power to the heater tank at too high a temperature Showerhead spray plate blocked Turn the temperature knob sufficiently anticlockwise to increase the water flow a...

Страница 20: ...hority undertaker Check water supply static pressure Note Static pressure may fall below 0 2 bar when other appliances are operated e g dishwasher washing machine etc Power neon goes off when unit is...

Страница 21: ...aning Many household cleaners contain abrasives and chemical substances and should not be used for cleaning plated or plastic fittings These finishes should be cleaned with a mild washing up detergent...

Страница 22: ...off inlet water supply 1 Remove the three cover retaining screws the cover and the service tunnel 2 Remove the screws that hold the inlet clamp bracket in position and remove the clamp bracket 3 Loos...

Страница 23: ...6 025 Service Tunnel 1563 527 Terminal Block A A B B B B B 1563 509 Switching Assembly 872 01 Microswitch N O 2 pin 1563 514 Low Flow Neon Assy 1563 515 Power On Neon Assy B 1563 516 Outlet Connector...

Страница 24: ...product or consequential loss of any kind Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed representative Routine maintenance or replac...

Отзывы: