Kohler Mira Mira Sprint Скачать руководство пользователя страница 16

16

1.  Switch on

 the pullcord or wall 

mounted switch. The 

power 

neon will provide a visual 

indication that the switch is on.

2.

  Press the 

start

 button.

3.

  Rotate the 

top

 control knob to 

the 

HIGH

 position

 

(Full Power).

4.

 Wait 

15-20

 seconds for warm 

water to reach the showerhead.

5.

  If necessary turn the 

bottom

 

control knob slowly to adjust 

temperature.  Allow 

10-15 

seconds for the adjusted 

temperature to reach the 

showerhead. The control knob 

operates through approximately 

¾ of a turn from cold to hot.

 

Clockwise rotation will give 

warmer water with less flow. 

Anticlockwise rotation will give 

cooler water with more flow.

6.  To turn off

 the Mira Sprint press 

the 

stop

 button. The appliance 

will continue to run for a few 

seconds before stopping.

7.

  A  small  amount  of  water  may 

be retained in the showerhead 

after the shower control has 

been turned off. This may drain 

over a few minutes.

 

F o r   s u m m e r   e c o n o m y 

showering use position

 ECO

 

(Half Power) on the control. For 

a cold shower select 

LOW

.

8.  Switch off

  pull-cord  or  wall 

mounted switch.

=

=

=

=

=

COLD

Stop Start

Stop Start

ECO

Hotter

Press to Start/

Stop

Cooler

HIGH

LOW

Operating Instructions

Caution! 

Always check the temperature before entering the shower. The previous 

user may have selected a 

different

 temperature setting.

Содержание Mira Sprint

Страница 1: ...1 Stop Start Mira Sprint 8 5 9 5 kW These instructions must be left with the user Installation and User Guide For SPARES ADVICE or REPAIRS Please call us on 0844 571 5000 UK Only...

Страница 2: ...trols for power selection and for temperature flow adjustment A unique flow regulator stabilises any temperature changes caused by water pressure fluctuations which can result from taps being turned o...

Страница 3: ...is properly insulated 5 DO NOT switch the shower on if there is a possibility that the water in the shower is frozen 6 DO NOT switch the shower on if water starts leaking from the shower case Isolate...

Страница 4: ...boxes to familiarise yourself with the part names and to confirm that the parts are included 1 x Mira Sprint Electric Shower 3 x Wall Plugs 3 x Fixing Screws 1 x Installation and User Guide 1 x Guara...

Страница 5: ...108 EC EMC Directive The Mira Sprint range of showers are high power appliances and are subject to conditional connection If the main electrical supply fuse is rated less than 80 Amps the local elect...

Страница 6: ...CaCO3 Outlet Connection 1 2 BSP Male Electrical Variant Sprint 8 5 Sprint 9 5 Nominal Power at 230 V ac 7 8 kW 8 7 kW Nominal Power at 240 V ac 8 5 kW 9 5 kW Recommended MCB Rating 40 A 40 A Maximum S...

Страница 7: ...on within the shower area and is fitted with a pressure relief valve It must be positioned over a water catchment area with the controls at a convenient height for the user 6 The shower must be fitted...

Страница 8: ...ctions caused by excessive limescale formation are not covered by this shower s guarantee see back page for details 18 The installation must not cause the hose to be sharply kinked during normal use D...

Страница 9: ...m A separate supply must be provided from the consumer unit to the shower 5 DO NOT supply any other electrical equipment including extractor fans or pumps via this product 6 This shower must be provid...

Страница 10: ...let the connection to the inlet connector must still be made from the top or bottom through a bend Warning To avoid damage to the case when soldered fittings are used pre solder the pipework and fitti...

Страница 11: ...Caution DO NOT twist the individual cable cores of the live and neutral conductors as this will prevent them from entering the terminal block 15 Fit an earth sleeve to the earth conductor Connect the...

Страница 12: ...Cover Retaining Screws Do not fit the Mira Sprint to the wall and tile up to the case The Mira Sprint must be fitted on to a finished flat and even wall surface small pillars on the back of the case...

Страница 13: ...ing from the bottom of the case 4 Turn the top control knob to the LOW position 5 Switch on the electrical supply at the double pole switch The power neon will provide a visual indication that the ele...

Страница 14: ...this shows that the full power setting is operating correctly 10 Set the shower temperature by rotating the bottom knob as necessary Turn the knob clockwise for hotter water and anticlockwise for cool...

Страница 15: ...all electrical appliances 8 DO NOT connect the outlet of the shower to any tap control valve trigger handset or showerhead other than those specified for use with this shower Only Kohler Mira recommen...

Страница 16: ...er with less flow Anticlockwise rotation will give cooler water with more flow 6 To turn off the Mira Sprint press the stop button The appliance will continue to run for a few seconds before stopping...

Страница 17: ...ing the thermal trip to operate and cut the power to the heater tank Showerhead sprayplate blocked Other outlets being used whilst showering causing water pressure to drop below minimum required to op...

Страница 18: ...he cover of the appliance Only a competent tradesperson should remove the cover Key light illuminated A POWER indicator B LOW FLOW indicator Malfunction A B Cause Remedy No water or very low flow rate...

Страница 19: ...switch is incorporated that cuts the power to the heater tank at too high a temperature Showerhead spray plate blocked Turn the temperature knob sufficiently anticlockwise to increase the water flow a...

Страница 20: ...hority undertaker Check water supply static pressure Note Static pressure may fall below 0 2 bar when other appliances are operated e g dishwasher washing machine etc Power neon goes off when unit is...

Страница 21: ...aning Many household cleaners contain abrasives and chemical substances and should not be used for cleaning plated or plastic fittings These finishes should be cleaned with a mild washing up detergent...

Страница 22: ...off inlet water supply 1 Remove the three cover retaining screws the cover and the service tunnel 2 Remove the screws that hold the inlet clamp bracket in position and remove the clamp bracket 3 Loos...

Страница 23: ...6 025 Service Tunnel 1563 527 Terminal Block A A B B B B B 1563 509 Switching Assembly 872 01 Microswitch N O 2 pin 1563 514 Low Flow Neon Assy 1563 515 Power On Neon Assy B 1563 516 Outlet Connector...

Страница 24: ...product or consequential loss of any kind Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed representative Routine maintenance or replac...

Отзывы: