The preferred method of fixing which is suitable for almost all situations is
the cable fixing method which is described in the following section in detail.
The fire may be secured using the cable method as described below, or alterna-
tively, in installations where the cable method is not suitable (eg. loose masonary
in rear of fire opening)
To fit using the
preferred
cable method proceed as follows-
h)
Mark out and drill 4 off No 14 (6mm) holes in the back face of the fire
opening in the positions shown below in figure 11
Fig. 11
Fit the wallplugs provided and screw the fixing eyes securely into the rear of the
fire opening. If the clearance at the rear of the fire is at the minimum specified for
a precast flue application, it may be necessary to bend over the lower fixing eyes
after screwing them fully in to the rear of a pre-cast starter block.
i)
Uncoil the two fire fixing cables and thread one end of each of the
cables through one of the two holes on each side of the flue outlet
shroud.
j)
Position the fire carefully on the (protected) surface of the hearth and
reach into the fire opening. Thread each of the cables vertically
downwards through the pair of fixing eyes on the same side of the fire.
Thread the free end of the cables through the corresponding circular
hole on each side of the lower rear of the fire. Carefully slide the fire
box back into the fire opening and pull both cables tight.
16
20mm
500mm
Fireplace Opening
100mm
250mm