IMPORTANT : Sealing of the Gas Unused Gas Pipe Inlet Apertures
In line with current GAS SAFE regulations,
it is imperative that the gas supply
inlet apertures that are not utilised during the installation are sealed with the
foil tape as supplied
. Failure to seal these inlet apertures could lead to flame
reversal, which in turn will damage the burner and control systems of the product.
Figure 10 below shows a correctly sealed installation.
Fig. 10
PLEASE NOTE :-
Seal off unused gas inlet
apertures and cable fixing holes
as shown
Only holes to be left are the specifically
sized air relief holes as indicated by the
labels positioned by them and the gas
inlet aperture that is used
BFM EUROPE LTD WILL NOT BE LIABLE FOR
GUARANTEE CLAIMS THAT ARE AS A DIRECT
RESULT OF THE UNUSED GAS INLET APERTURES
NOT BEING CORRECTLY SEALED.
15