Made to Order

The 110 series Solenoid Valves include a variety of made to order
solenoids for application in a wider range of control and wiring types.

Straight connector

with LED indicator

Without lead wire

Connector and contacts included

When ordering, enter  

-PSLN or -PSLL in place of the

normal option code for the wiring type.

-PSLN

Lead wire length

For plug connector

Length  mm [in.]

-1L

1000 [39]

-3L

3000 [118]

For lead wire length, 

-1L  is 1000mm [39in.] and -3L  is

3000mm [118in.].
When ordering, enter 

-1L or  -3L following the wiring type

option code.

-1L

-3L

L connector 

with LED indicator

Without lead wire

Connector and contacts included

-PLLN

-39

A compact connector that is highly resistant to
dust and water splashes.
Employs a self-stripping method that
eliminates the need for de-sheathing the lead
wire.

LED indicator

-L

The LED indicator for confirmation of
operation is also available without a plug
connector. This creates a clean monoblock
look with a compact cover.

When ordering, enter 

-39 in place of the normal option code for

the wiring type.

A varistor for surge suppression is also equipped.
(For the AC100V and AC200V only. For DC12V and DC24V, a
flywheel diode for surge suppression is installed as standard
equipment.)

LED indicator is not available.

When ordering, enter 

-L in place of the normal option code for

the wiring type.

A varistor for surge suppression is also equipped.

(For the AC100V and AC200V only. For the DC12V and
DC24V, a flywheel diode for surge suppression is installed as
standard equipment.)

Wiring instructions

Solenoid with DIN connector

When de-sheathing (only the outer sheath of the cabtyre), pay attention
to the lead wire direction. The cover will be easily mounted when the
lead wire on the outer side of the terminal cover is set about 8mm
[0.31in.] longer than the inner side.
Without stripping off the sheath, insert the lead until it contacts the lead
wire stopper on the terminal body, and then place the contact from the
upper side. Then use pliers to press the lead wire further to ensure that
the contact is firmly touching the core wire.

2

1

3

+

_

Cable

Cable gland

Cable gasket
Washer

Gasket

Gasket

Cover mounting 

screw

Terminal cover

Lead wire

Terminal body

Pliers

Solenoid terminal 

arrangement

JIS C3306

VCTF Conductor 0.75mm

2

 [0.00116in.

2

Finished outside 6.6mm [0.260in.]

2 leads

                           7.0mm [0.276in.]

3 leads

Contact
Lead wire 

stopper

Note

Terminal body

Lead wire

Note: The appropriate tightening torque for the cover mounting screw is

29.4N

G

cm {3kgf

G

cm} [2.6in

G

lbf].

Plug connector

DIN connector

CE Marking compliant product

*Excluding tandem solenoid valves.

The 180 series Solenoid Valves include a variety of made to order
solenoids for application in a wider range of control and wiring types.

Made to Order

The 110 series Solenoid Valves include a variety of made to order
solenoids for application in a wider range of control and wiring types.

Straight connector

with LED indicator

Without lead wire

Connector and contacts included

When ordering, enter  

-PSLN or -PSLL in place of the

normal option code for the wiring type.

-PSLN

Lead wire length

For plug connector

Length  mm [in.]

-1L

1000 [39]

-3L

3000 [118]

For lead wire length, 

-1L  is 1000mm [39in.] and -3L  is

3000mm [118in.].
When ordering, enter 

-1L or  -3L following the wiring type

option code.

-1L

-3L

L connector 

with LED indicator

Without lead wire

Connector and contacts included

-PLLN

-39

A compact connector that is highly resistant to
dust and water splashes.
Employs a self-stripping method that
eliminates the need for de-sheathing the lead
wire.

LED indicator

-L

The LED indicator for confirmation of
operation is also available without a plug
connector. This creates a clean monoblock
look with a compact cover.

When ordering, enter 

-39 in place of the normal option code for

the wiring type.

A varistor for surge suppression is also equipped.
(For the AC100V and AC200V only. For DC12V and DC24V, a
flywheel diode for surge suppression is installed as standard
equipment.)

LED indicator is not available.

When ordering, enter 

-L in place of the normal option code for

the wiring type.

A varistor for surge suppression is also equipped.

(For the AC100V and AC200V only. For the DC12V and
DC24V, a flywheel diode for surge suppression is installed as
standard equipment.)

Wiring instructions

Solenoid with DIN connector

When de-sheathing (only the outer sheath of the cabtyre), pay attention
to the lead wire direction. The cover will be easily mounted when the
lead wire on the outer side of the terminal cover is set about 8mm
[0.31in.] longer than the inner side.
Without stripping off the sheath, insert the lead until it contacts the lead
wire stopper on the terminal body, and then place the contact from the
upper side. Then use pliers to press the lead wire further to ensure that
the contact is firmly touching the core wire.

2

1

3

+

_

Cable

Cable gland

Cable gasket
Washer

Gasket

Gasket

Cover mounting 

screw

Terminal cover

Lead wire

Terminal body

Pliers

Solenoid terminal 

arrangement

JIS C3306

VCTF Conductor 0.75mm

2

 [0.00116in.

2

Finished outside 6.6mm [0.260in.]

2 leads

                           7.0mm [0.276in.]

3 leads

Contact
Lead wire 

stopper

Note

Terminal body

Lead wire

Note: The appropriate tightening torque for the cover mounting screw is

29.4N

G

cm {3kgf

G

cm} [2.6in

G

lbf].

Plug connector

DIN connector

CE Marking compliant product

*Excluding tandem solenoid valves.

CE Marking compliant product

*Excluding tandem solenoid valves.

When ordering,enter -39 in place of the normal 

  

option code for the wiring type.

LED indicator is not available.

Wiring Outline

1.  Loosen the mounting thread of the connector, and remove it from the
     valve.
2.  After removing the mounting thread from the connector, pry the cutout- 
     part from terminal block with the screwdriver to separate the terminal 
     block and the housing. 
3.  Thread gland nut, washer, grommet to the cable, and plug into the
     wiring port of housing. Insert the conductor to the contact of terminal
     block, and tighten the terminal thread to fix the lead wire.

Wiring Port Direction

1.  In order to alter the direction of wiring port, change the direction of
     terminal body by 90 degrees when putting the terminal body into
     terminal cover.

Use φ4-φ7 outer diameter cable.

    (REFERENCE)Equal to JISC3306 0.5mm

2

 double core cable and triple

    core cable

Contact

Terminal Screw

Mounting Screw

(ー)

(+)

Grommet

Washer

Ground nut

Cutout-part

Terminal Block

Housing

Ground

1

2

+

(Electrical ground)

DIN connector

Plug connector

Wiring Outline

Wiring Port Direction

Compatible Cab Tire Cord

LED indicator

The 180 series Solenoid Valves include a variety of made to order
solenoids for application in a wider range of control and wiring types.

Made to Order

The 110 series Solenoid Valves include a variety of made to order
solenoids for application in a wider range of control and wiring types.

Straight connector

with LED indicator

Without lead wire

Connector and contacts included

When ordering, enter  

-PSLN or -PSLL in place of the

normal option code for the wiring type.

-PSLN

Lead wire length

For plug connector

Length  mm [in.]

-1L

1000 [39]

-3L

3000 [118]

For lead wire length, 

-1L  is 1000mm [39in.] and -3L  is

3000mm [118in.].
When ordering, enter 

-1L or  -3L following the wiring type

option code.

-1L

-3L

L connector 

with LED indicator

Without lead wire

Connector and contacts included

-PLLN

-39

A compact connector that is highly resistant to
dust and water splashes.
Employs a self-stripping method that
eliminates the need for de-sheathing the lead
wire.

LED indicator

-L

The LED indicator for confirmation of
operation is also available without a plug
connector. This creates a clean monoblock
look with a compact cover.

When ordering, enter 

-39 in place of the normal option code for

the wiring type.

A varistor for surge suppression is also equipped.
(For the AC100V and AC200V only. For DC12V and DC24V, a
flywheel diode for surge suppression is installed as standard
equipment.)

LED indicator is not available.

When ordering, enter 

-L in place of the normal option code for

the wiring type.

A varistor for surge suppression is also equipped.

(For the AC100V and AC200V only. For the DC12V and
DC24V, a flywheel diode for surge suppression is installed as
standard equipment.)

Wiring instructions

Solenoid with DIN connector

When de-sheathing (only the outer sheath of the cabtyre), pay attention
to the lead wire direction. The cover will be easily mounted when the
lead wire on the outer side of the terminal cover is set about 8mm
[0.31in.] longer than the inner side.
Without stripping off the sheath, insert the lead until it contacts the lead
wire stopper on the terminal body, and then place the contact from the
upper side. Then use pliers to press the lead wire further to ensure that
the contact is firmly touching the core wire.

2

1

3

+

_

Cable

Cable gland

Cable gasket
Washer

Gasket

Gasket

Cover mounting 

screw

Terminal cover

Lead wire

Terminal body

Pliers

Solenoid terminal 

arrangement

JIS C3306

VCTF Conductor 0.75mm

2

 [0.00116in.

2

Finished outside 6.6mm [0.260in.]

2 leads

                           7.0mm [0.276in.]

3 leads

Contact
Lead wire 

stopper

Note

Terminal body

Lead wire

Note: The appropriate tightening torque for the cover mounting screw is

29.4N

G

cm {3kgf

G

cm} [2.6in

G

lbf].

Plug connector

DIN connector

CE Marking compliant product

*Excluding tandem solenoid valves.

CE Marking compliant product

*Excluding tandem solenoid valves.

When ordering,enter -39 in place of the normal 

  

option code for the wiring type.

LED indicator is not available.

Wiring Outline

1.  Loosen the mounting thread of the connector, and remove it from the
     valve.
2.  After removing the mounting thread from the connector, pry the cutout- 
     part from terminal block with the screwdriver to separate the terminal 
     block and the housing. 
3.  Thread gland nut, washer, grommet to the cable, and plug into the
     wiring port of housing. Insert the conductor to the contact of terminal
     block, and tighten the terminal thread to fix the lead wire.

Wiring Port Direction

1.  In order to alter the direction of wiring port, change the direction of
     terminal body by 90 degrees when putting the terminal body into
     terminal cover.

Use φ4-φ7 outer diameter cable.

    (REFERENCE)Equal to JISC3306 0.5mm

2

 double core cable and triple

    core cable

Contact

Terminal Screw

Mounting Screw

(ー)

(+)

Grommet

Washer

Ground nut

Cutout-part

Terminal Block

Housing

Ground

1

2

+

(Electrical ground)

DIN connector

Plug connector

Wiring Outline

Wiring Port Direction

Compatible Cab Tire Cord

LED indicator

The 180 series Solenoid Valves include a variety of made to order
solenoids for application in a wider range of control and wiring types.

Made to Order

The 110 series Solenoid Valves include a variety of made to order
solenoids for application in a wider range of control and wiring types.

Straight connector

with LED indicator

Without lead wire

Connector and contacts included

When ordering, enter  

-PSLN or -PSLL in place of the

normal option code for the wiring type.

-PSLN

Lead wire length

For plug connector

Length  mm [in.]

-1L

1000 [39]

-3L

3000 [118]

For lead wire length, 

-1L  is 1000mm [39in.] and -3L  is

3000mm [118in.].
When ordering, enter 

-1L or  -3L following the wiring type

option code.

-1L

-3L

L connector 

with LED indicator

Without lead wire

Connector and contacts included

-PLLN

-39

A compact connector that is highly resistant to
dust and water splashes.
Employs a self-stripping method that
eliminates the need for de-sheathing the lead
wire.

LED indicator

-L

The LED indicator for confirmation of
operation is also available without a plug
connector. This creates a clean monoblock
look with a compact cover.

When ordering, enter 

-39 in place of the normal option code for

the wiring type.

A varistor for surge suppression is also equipped.
(For the AC100V and AC200V only. For DC12V and DC24V, a
flywheel diode for surge suppression is installed as standard
equipment.)

LED indicator is not available.

When ordering, enter 

-L in place of the normal option code for

the wiring type.

A varistor for surge suppression is also equipped.

(For the AC100V and AC200V only. For the DC12V and
DC24V, a flywheel diode for surge suppression is installed as
standard equipment.)

Wiring instructions

Solenoid with DIN connector

When de-sheathing (only the outer sheath of the cabtyre), pay attention
to the lead wire direction. The cover will be easily mounted when the
lead wire on the outer side of the terminal cover is set about 8mm
[0.31in.] longer than the inner side.
Without stripping off the sheath, insert the lead until it contacts the lead
wire stopper on the terminal body, and then place the contact from the
upper side. Then use pliers to press the lead wire further to ensure that
the contact is firmly touching the core wire.

2

1

3

+

_

Cable

Cable gland

Cable gasket
Washer

Gasket

Gasket

Cover mounting 

screw

Terminal cover

Lead wire

Terminal body

Pliers

Solenoid terminal 

arrangement

JIS C3306

VCTF Conductor 0.75mm

2

 [0.00116in.

2

Finished outside 6.6mm [0.260in.]

2 leads

                           7.0mm [0.276in.]

3 leads

Contact
Lead wire 

stopper

Note

Terminal body

Lead wire

Note: The appropriate tightening torque for the cover mounting screw is

29.4N

G

cm {3kgf

G

cm} [2.6in

G

lbf].

Plug connector

DIN connector

CE Marking compliant product

*Excluding tandem solenoid valves.

CE Marking compliant product

*Excluding tandem solenoid valves.

When ordering,enter -39 in place of the normal 

  

option code for the wiring type.

LED indicator is not available.

Wiring Outline

1.  Loosen the mounting thread of the connector, and remove it from the
     valve.
2.  After removing the mounting thread from the connector, pry the cutout- 
     part from terminal block with the screwdriver to separate the terminal 
     block and the housing. 
3.  Thread gland nut, washer, grommet to the cable, and plug into the
     wiring port of housing. Insert the conductor to the contact of terminal
     block, and tighten the terminal thread to fix the lead wire.

Wiring Port Direction

1.  In order to alter the direction of wiring port, change the direction of
     terminal body by 90 degrees when putting the terminal body into
     terminal cover.

Use φ4-φ7 outer diameter cable.

    (REFERENCE)Equal to JISC3306 0.5mm

2

 double core cable and triple

    core cable

Contact

Terminal Screw

Mounting Screw

(ー)

(+)

Grommet

Washer

Ground nut

Cutout-part

Terminal Block

Housing

Ground

1

2

+

(Electrical ground)

DIN connector

Plug connector

Wiring Outline

Wiring Port Direction

Compatible Cab Tire Cord

LED indicator

The 180 series Solenoid Valves include a variety of made to order
solenoids for application in a wider range of control and wiring types.

Содержание 180 Series

Страница 1: ...INSTRUCTION MANUAL Ver 1 0 BK UV002 Ver 1 0 SOLENOID VALVES 180 SERIES Air Valve BK UV002 Ver 1 1 Ver 1 1 ...

Страница 2: ...using in the locations and environment listed below as it could result in malfunction of the valve If use in such conditions is unavoidable always provide a cover or other adequate protective measures Location directly exposed to water drops or oil drops Environment where a valve body is subject to dew condensation Location directly exposed to machining chips dust etc 3 Install a muffler etc in th...

Страница 3: ...r wire DC12V Black DC24V Black w and e are for with DIN connector Order code 39 w and e are for with DIN connector Order code 39 w e Short circuit protection diode Solenoid Flywheel diode Lead wire DC12V Brown Lead wire Black DC24V Red LED indicator Red Lead wire Black Lead wire DC12V Brown LED indicator Light Emitting Diode DC24V Red Solenoid Lead wire AC100V Yellow Varistor or w e e w or AC200V ...

Страница 4: ...n the clockwise direction as far as position A This achieves the same conditions as when the 14 SA side is energized and the manual override button manual lever is locked in place For the 12 SB side turn it in the counterclockwise direction as far as position B To release the lock return the manual override button manual lever to the 0 position A spring mechanism returns the manual override button...

Страница 5: ...g types variety of made to order ol and wiring types the nd 3L is wiring type 39 A compact connector that is highly resistant to dust and water splashes Employs a self stripping method that eliminates the need for de sheathing the lead wire LED indicator L The LED indicator for confirmation of operation is also available without a plug connector This creates a clean monoblock look with a compact c...

Отзывы: