K441XX Automatic Non-Woods Metal Noack Evaporative Apparatus  

Operation and Instruction Manual 

 

K441XX-Manual 

- 16 - 

8 Service

 

 

Under normal operating conditions and with 

routine maintenance, the K44100 Noack 
Evaporation Tester should not require service. Any 
service problem can be quickly resolved by 
contacting Koehler’s technical service department 
either by letter, phone, fax, or email. In order to 
assure the fastest possible service, please provide 
us with the following information. 

 
Model Number:   

 

 

 

Serial Number:   

 

 

 

Date of Shipment:   

 

 

 

 

9 Storage

 

 

This laboratory test instrument is equipped with 

electrical components. Storage facilities should be 
consistent with an indoor laboratory environment. 
This testing equipment should not be subjected to 
extremes of temperature and/or moisture. 
 

This equipment was shipped from the factory in a 

corrugated cardboard container. If long term 
storage is anticipated, re-packing the instrument in 
a water-resistant container is recommended to 
ensure equipment safety and longevity. 

 

10 Warranty

 

 

We at Koehler would like to thank you for your 

equipment purchase, which is protected by the 
following warranty. If within one (1) year from the 
date of receipt, but no longer than fifteen (15) 
months from the date of shipment, Koehler 
equipment fails to perform properly because of 
defects in materials or workmanship, Koehler 
Instrument Company, Inc. will repair or, at its sole 
discretion, replace the equipment without charge 
F.O.B. its plant, provided the equipment has been 
properly installed, operated, and maintained. 
Koehler Instrument Company must be advised in 
writing of the malfunction and authorize the return 
of the product to the factory. The sole responsibility 
of Koehler Instrument Company and the 
purchaser’s exclusive remedy for any claim arising 
out of the purchase of any product is the repair or 
replacement of the product. In no event shall the 
cost of the purchaser’s remedy exceed the 
purchase price, nor shall Koehler Instrument 
Company be liable for any special, indirect, 
incidental, consequential, or exemplary damages. 

KOEHLER INSTRUMENT COMPANY, INC. 
DISCLAIMS ALL OTHER WARRANTIES, 
EXPRESSED OR IMPLIED, INCLUDING ANY 
IMPLIED WARRANTIES OF FITNESS FOR A 
PARTICULAR PURPOSE. Please save the 
shipping carton in the event the equipment needs to 
be returned to the factory for warranty repair. If the 
carton is discarded, it will be the purchaser’s 
responsibility to provide an appropriate shipping 
carton. 
 

11  Returned Goods Policy

 

 

To return products for credit or replacement, please 
contact Koehler Customer Service with your 
purchase order number, our packing list/invoice 
number, the item(s) to be returned and the reason 
for the return. You will be issued a Returned 
Authorization (RA) number, which must be 
prominently displayed on the shipping container 
when you return the material to our plant. Shipping 
containers without an RA number prominently 
displayed with be returned to the sender. Goods 
must be returned freight prepaid. Returns will be 
subject to a restocking charge, the application of 
which will depend upon the circumstances 
necessitating the return. Some returns cannot be 
authorized, including certain products purchased 
from outside vendors for the convenience of the 
customer, products manufactured on special order, 
products shipped from the factory past ninety (90) 
days, and products which have been used or 
modified in such a way that they cannot be returned 
to stock for future sale. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Содержание K44100

Страница 1: ...mia New York 11716 1796 USA Toll Free 1 800 878 9070 US only Tel 1 631 589 3800 Fax 1 631 589 3815 http www koehlerinstrument com e mail info koehlerinstrument com Petroleum Testing Analysis Instrumen...

Страница 2: ...1...

Страница 3: ...Packing List 5 3 2 Unpacking 5 3 3 Installation 5 3 4 Additional Accessories Required for Running Tests 5 3 5 Optional Accessories Available 5 4 Descriptions 6 4 1 Piping Diagram 6 4 2 Instrument Cont...

Страница 4: ...s manual should also be used in conjunction with applicable published laboratory procedures Information on these procedures is given in section 1 2 1 1 Koehler s Commitment to Our Customers Providing...

Страница 5: ...to access the analyzer STAY ALERT Do not operate this unit while under the influence of medication alcohol or drugs Equipment Modifications and Replacement Parts Any modification or alteration of thi...

Страница 6: ...shipping container and equipment Do not return goods to Koehler without written authorization 3 3 Installation Equipment Placement Place the instrument on a firm surface in a secure area 1 Connect th...

Страница 7: ...6 4 Descriptions 4 1 Piping Diagram Figure 1 Piping Diagram...

Страница 8: ...K441XX Automatic Non Woods Metal Noack Evaporative Apparatus Operation and Instruction Manual K441XX Manual 7 4 2 Instrument Controls and Connections Figure 2 Top Front Left Side View...

Страница 9: ...K441XX Automatic Non Woods Metal Noack Evaporative Apparatus Operation and Instruction Manual K441XX Manual 8 Figure 3 Top Left Back Side View Figure 4 Analyzer Complete with Assembled Glassware Set...

Страница 10: ...bration date Figure 7 Calibration Screen 4 On the left side of the screen a graph shows the calibration curve along with the selected probe s value in both C and volts 5 On the right side of the scree...

Страница 11: ...emperature Control via PT100 probe in the Heating Block Bath Method B Temperature Control via PT100 probe in the Crucible 4 Select the set point temperature for the test based on the selected method S...

Страница 12: ...egulate the aspiration vacuum to 2 mbar by slowly closing the bleed valve halfway and regulating the vacuum regulator on the analyzer s side in order to reach 20 0 2mm on the inclined manometer 2mbar...

Страница 13: ...for 30 minutes NOTE WHILE REMOVING THE CRUCIBLE AND PLACING IT IN THE WATER BATH MAKE SURE THE SAMPLE DOES NOT SPLASH THE CRUCIBLE S COVER 7 After 30 minutes carefully dry the outside of the crucible...

Страница 14: ...e operator to select the sample o Press the Load Analysis Button in between the two arrows to view the analysis Figure 13 Results Browser Main Screen If the final weight has not been introduced a ques...

Страница 15: ...hler Representative as each printer has different characteristics and specific drivers Touching the Show Details button causes the analysis to reload and the data to be displayed second by second on t...

Страница 16: ...test is run clean the Woullf bottles and pipes Each time a test is run clean the heating jacket Periodically clean the vacuum filter 7 2 Replacement Parts Some instrument parts may need to be replaced...

Страница 17: ...rize the return of the product to the factory The sole responsibility of Koehler Instrument Company and the purchaser s exclusive remedy for any claim arising out of the purchase of any product is the...

Страница 18: ...K441XX Automatic Non Woods Metal Noack Evaporative Apparatus Operation and Instruction Manual K441XX Manual 17 Notes...

Страница 19: ...K441XX Automatic Non Woods Metal Noack Evaporative Apparatus Operation and Instruction Manual K441XX Manual 18 Notes...

Страница 20: ...K441XX Automatic Non Woods Metal Noack Evaporative Apparatus Operation and Instruction Manual K441XX Manual 19 Notes...

Отзывы: