Koehler K44100 Скачать руководство пользователя страница 14

K441XX Automatic Non-Woods Metal Noack Evaporative Apparatus  

Operation and Instruction Manual 

 

K441XX-Manual 

- 13 - 

6.5  The Results Browser 

 

  Every analysis performed is automatically 

recorded.  The results browser grants access 
to the analysis archive.   

  Use the two arrows on the top of the screen 

to choose the month/year. See Figure 13 
below: 

 

o

  The Month’s corresponding days 

are shown in gray if no analysis 
has been performed.  

o

  The day is shown in black if the day 

holds more than one analysis 

o

  When a day is selected, a green 

box will appear around that day 

 

  From top to bottom the analysis are enlisted 

in order of time: 

 

o

 

For example in the picture below 
the two analysis where performed 
at 01:38:14 and 02:18:48 on June 
25, 2010.  

 

 

A - sign (as shown in sample 1) 
means a final weight has not 
been entered

 

  A ± sign (as shown in sample 

2) means the sample has been 
fully completed. 

o

  The two arrows located on the side 

allow the operator to select the 
sample. 

o

 Press 

the 

Load Analysis Button

 (in 

between the two arrows) to view 
the analysis. 

 

 

 

Figure 13: Results Browser Main Screen 

 
If the final weight has not been introduced a 
question mark will appear in the 

C Sample 

Final Weight 

Field as shown in Figure 14: 

 

 

Figure 14: Incomplete Final Weight Screen 

 
To enter the final result, or review any previous 
parameters, press the 

Review Analysis 

button (top 

button on the right hand side). See Figure 15 below: 

 

 

 

Figure 15: Review Analysis Screen 

 

Once the final weight is entered the result will 
automatically be calculated according to the method 
chosen.  It is also possible to review/change the 
other parameters by selecting the 

Change

 button 

located on the right hand side of the shown values.   
 
Once the final weight has been introduced press 
the 

ACCEPT

 button to confirm, or 

CANCEL

 to 

discard the changes and close the panel. Refer to 
Figure 15 above.  
 
Once the analysis has been reviewed and 
completed with the final weight, the result browser 
will automatically show the result and the equivalent 
result for the other available method. See Figure 
16: 

Содержание K44100

Страница 1: ...mia New York 11716 1796 USA Toll Free 1 800 878 9070 US only Tel 1 631 589 3800 Fax 1 631 589 3815 http www koehlerinstrument com e mail info koehlerinstrument com Petroleum Testing Analysis Instrumen...

Страница 2: ...1...

Страница 3: ...Packing List 5 3 2 Unpacking 5 3 3 Installation 5 3 4 Additional Accessories Required for Running Tests 5 3 5 Optional Accessories Available 5 4 Descriptions 6 4 1 Piping Diagram 6 4 2 Instrument Cont...

Страница 4: ...s manual should also be used in conjunction with applicable published laboratory procedures Information on these procedures is given in section 1 2 1 1 Koehler s Commitment to Our Customers Providing...

Страница 5: ...to access the analyzer STAY ALERT Do not operate this unit while under the influence of medication alcohol or drugs Equipment Modifications and Replacement Parts Any modification or alteration of thi...

Страница 6: ...shipping container and equipment Do not return goods to Koehler without written authorization 3 3 Installation Equipment Placement Place the instrument on a firm surface in a secure area 1 Connect th...

Страница 7: ...6 4 Descriptions 4 1 Piping Diagram Figure 1 Piping Diagram...

Страница 8: ...K441XX Automatic Non Woods Metal Noack Evaporative Apparatus Operation and Instruction Manual K441XX Manual 7 4 2 Instrument Controls and Connections Figure 2 Top Front Left Side View...

Страница 9: ...K441XX Automatic Non Woods Metal Noack Evaporative Apparatus Operation and Instruction Manual K441XX Manual 8 Figure 3 Top Left Back Side View Figure 4 Analyzer Complete with Assembled Glassware Set...

Страница 10: ...bration date Figure 7 Calibration Screen 4 On the left side of the screen a graph shows the calibration curve along with the selected probe s value in both C and volts 5 On the right side of the scree...

Страница 11: ...emperature Control via PT100 probe in the Heating Block Bath Method B Temperature Control via PT100 probe in the Crucible 4 Select the set point temperature for the test based on the selected method S...

Страница 12: ...egulate the aspiration vacuum to 2 mbar by slowly closing the bleed valve halfway and regulating the vacuum regulator on the analyzer s side in order to reach 20 0 2mm on the inclined manometer 2mbar...

Страница 13: ...for 30 minutes NOTE WHILE REMOVING THE CRUCIBLE AND PLACING IT IN THE WATER BATH MAKE SURE THE SAMPLE DOES NOT SPLASH THE CRUCIBLE S COVER 7 After 30 minutes carefully dry the outside of the crucible...

Страница 14: ...e operator to select the sample o Press the Load Analysis Button in between the two arrows to view the analysis Figure 13 Results Browser Main Screen If the final weight has not been introduced a ques...

Страница 15: ...hler Representative as each printer has different characteristics and specific drivers Touching the Show Details button causes the analysis to reload and the data to be displayed second by second on t...

Страница 16: ...test is run clean the Woullf bottles and pipes Each time a test is run clean the heating jacket Periodically clean the vacuum filter 7 2 Replacement Parts Some instrument parts may need to be replaced...

Страница 17: ...rize the return of the product to the factory The sole responsibility of Koehler Instrument Company and the purchaser s exclusive remedy for any claim arising out of the purchase of any product is the...

Страница 18: ...K441XX Automatic Non Woods Metal Noack Evaporative Apparatus Operation and Instruction Manual K441XX Manual 17 Notes...

Страница 19: ...K441XX Automatic Non Woods Metal Noack Evaporative Apparatus Operation and Instruction Manual K441XX Manual 18 Notes...

Страница 20: ...K441XX Automatic Non Woods Metal Noack Evaporative Apparatus Operation and Instruction Manual K441XX Manual 19 Notes...

Отзывы: