background image

 

1-7 

SONAR SYSTEM SUMMARY

 

 

ECHO SOUNDER MODE 

 

The transmitter/receiver faces the sea bottom,

 

and emits the ultra-sound beam. The reflected

 

echo from the sea bottom is displayed on

 

the screen. The image is displayed like a

 

usual echo sounder.

 

 
 
 
 
 
 
 
 
 

The tilt angle and the direction can be changed.

 

 
 
 
 

The detecting direction can be set by

 

the Bearing keys.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

ECHO SOUNDER DISPLAY

DETECTS DIRECTLY UNDER THE SHIP

CHENGES THE TILT ANGLE

TILT ANGLE

CHENGES THE TILT ANGLE AND DIRECTION

 

TILT ANGLE

DIRECTION

Содержание ESR-S1BB

Страница 1: ......

Страница 2: ...81 554 20 58705 Identified by the type number ESR S1BB to which this declaration refers conforms to the relevant essential requirements of Directive 2004 108 EC and is in conformity with the EMC requi...

Страница 3: ...indicated at the lower right side on the cover and at the left or right side of the footer region of each page 2013 Koden Electronics Co Ltd All rights reserved No part of this publication may be repr...

Страница 4: ...ar We are confident you will enjoy using your unit for many years to come This manual provides complete information on safely operating the ESR S1BB Please carefully read and follow the safety informa...

Страница 5: ...injury indicates a potentially hazardous situation which if not avoided may result in minor injury NOTE CF Indicates the contents for the user s reference Pages for the user s reference NOTICE This ma...

Страница 6: ...t in dropping toppling over or injury Follow the below conditions for wirings Otherwise it cases heat a fire or injury Run the cables not to touch the rotary obstacles or disturb the operation Do not...

Страница 7: ...nel should work inside the unit Care for sufficient reinforcement and being watertight should be taken when installing the hoist Otherwise it will cause wrecks Use the proper fuse when changed Otherwi...

Страница 8: ...AR OPERATION 2 1 Operation Panel Key Operation 2 2 2 2 Operation Keys 2 3 Power ON OFF Key 2 3 Sonar Mode Key Off Center Mode Key Bottom Scan Echo Sounder Mode Key 2 4 2 4 2 4 Bearing Keys 2 5 Tilt ke...

Страница 9: ...Mode 3 15 Depth Unit 3 15 Temperature Unit 3 15 Speed Unit 3 15 Train Correct 3 16 Color Filter 3 17 3 18 Chapter 4 INSTALLATION 4 1 Installation Position 4 2 Dimensions 4 3 Transducer Unit Installati...

Страница 10: ...PONENTS Name of item OPERATION UNIT POWER SUPPLY CABLE 2m REMOTE CONTROLLER 4m Type ESR S1BB CW 206 2M OP 1409 Qty 1 1 1 Name of item FUSE OPERATION MANUAL Type F 7161 8A ESR S1BB OM E Qty 3 1 Continu...

Страница 11: ...1 50gx1 1EACH Name of item JOINT PIPE LOCK NUT RING TD CASE COVER Type Qty 1 1 1 1 1 Name of item LOW HEAD CAP BOLT CAP BOLT WASHER NUT BOLT Type M4x8 M8x16U SW8U N8U B8x25U Qty 4 4 4 2 2 SL 2 SET OP...

Страница 12: ...rmation of the PPI Plan Position Indicator searchlight sonar Sonar Mode 1 2 Tilt Angle 1 4 Tilt Angle and DIsplay 1 5 Bottom Scan Mode 1 6 Echo Sounder Mode 1 7 Sample Display of Sonar Mode 1 8 Sample...

Страница 13: ...he transducer protruded from the hull bottom The sonar principle detected by the transducer is the same with the echo sounder However like a searchlight the sonar transducer sends and detects ultra so...

Страница 14: ...so the vertical direction SONAR DISPLAY RANGE ECHO SOUNDER DISPLAY RANGE HORIZONTAL ANGLE SECTOR 180 WHEN DETECTING By changing the horizontal angle Sector the various ranges from the narrow to the fu...

Страница 15: ...angle the fish school is out of beam coverage at B position so that no reflection appears on the screen Set an appropriate tilt angle so that the reflection of fish school always appears on the screen...

Страница 16: ...e fish echo from the bottom since the distances from fish school and from bottom are the same TILT ANGLE 25 Fish school is clearly seen Fish school is displayed behind the bottom echo since fish schoo...

Страница 17: ...to side in the step set with STEP on MENU DISP ITEM SEL Changing the sector angle makes it possible to detect the wider or narrower range as desired The center direction of the sounding beam can be c...

Страница 18: ...om the sea bottom is displayed on the screen The image is displayed like a usual echo sounder The tilt angle and the direction can be changed The detecting direction can be set by the Bearing keys ECH...

Страница 19: ...E RANGE OPERATION MODE CROSS CURSOR VRM INTERFERENCE REDUCTION SEA BOTTOM ECHO SOUNDOME WATER TEMP POSITION SPEED LATITUDE LONGITUDE DEPTH SCALE SECTOR IR will not be displayed when INTER FERENCE RED...

Страница 20: ...LATITUDE LONGITUDE DEPTH SCALE RANGE The depth is displayed when the tilt angle is 90 IR will not be displayed when INTER FERENCE RED function OFF is selected M will not be displayed if OPERATION MODE...

Страница 21: ...n 2 2 Operation Keys 2 3 Power On Off Key 2 3 Sonar Mode key 2 4 Off Center Mode Key 2 4 Bottom Scan Echo Sounder Mode Key 2 4 Bearing Keys 2 5 Tilt Keys 2 6 Sector Keys 2 8 Range Keys 2 9 Operation M...

Страница 22: ...OLD KEY Reduces the unnecessary weak echoes accordingly 11 CURSOR SHIFT KEYS Moves the cursor or selects to display Marker or Cursor Use these keys to change the settings 12 ENTER KEY Press this key t...

Страница 23: ...2 3 SONAR OPERATION OPERATION KEYS POWER ON OFF KEY To turn on the power press ON key To turn off the power press OFF key for a while This key does not work by one push...

Страница 24: ...rd leftward on the screen CF page 3 11 BOTTOM SCAN ECHO SOUNDER MODE KEY Displays the Bottom Scan Mode or the Echo Sounder Mode BOTTOM SCAN MODE ECHO SOUNDER MODE The scanning direction is adjusted by...

Страница 25: ...arrow marks the center of the sector Use these keys to define the center of current scanning sector in the Bottom Scan Mode The bearing angle of the display is shifted with every 5 steps Counterclockw...

Страница 26: ...le range in increments of 3 step 3 90 and 3 on another side Variable range in increments of 5 step 5 90 and 5 on another side Refer to the page 3 11 for steps The angle center is just The center is se...

Страница 27: ...angle can be set in increments of 1 from 0 to 5 upward to 0 to 90 downward This angle is adjusted by the tilt keys Direction is adjusted by the bearing keys The depth is displayed when the tilt angle...

Страница 28: ...ode 5 STEP 5 25 45 85 125 165 205 360 10 STEP 10 30 50 90 130 170 210 360 Refer to the page 3 10 for steps Changes the sector angle vertical angle in the Bottom Scan Mode Changes this angle Each press...

Страница 29: ...F page 3 12 BASIC RANGE RANGE m br fm SONAR OFF CENTER BOTTOM SCAN ECHO SOUNDER SONAR OFF CENTER BOTTOM SCAN ECHO SOUNDER 0 10 15 10 10 15 10 1 20 30 20 20 30 20 2 30 45 30 30 45 30 3 40 60 40 40 60 4...

Страница 30: ...te that it may not be memorized when the key is released before you hear a beep By pressing the Operation Mode 1 or 2 key you hear a beep and the desired operation mode appears on the screen instantly...

Страница 31: ...the Ring Marker shifts the Cross Cursor downward or shifts VRM to the deeper area moves the highlighted item downward in the Menu shifts the Cross Cursor left selects the content of the item in the Me...

Страница 32: ...en In Echo Sounder Mode Marker data is presented and Slant distance appears on the screen When the Cross Cursor is selected the Ring Marker is in red or not displayed Set the Cross Cursor on a target...

Страница 33: ...Sonar Mode the sonar beam tracks the echo automatically When MENU TARGET LOCK MODE 1 or MODE 2 is selected The red letter TARGET LOCK is displayed at the position of both BEARING and SECTOR on the scr...

Страница 34: ...pressing this key again MAIN MENU disappears Pressing this key returns to MAIN MENU when the setup menu is displayed Use the Enter key to set the function item you changed ENTER KEY After you change t...

Страница 35: ...ied gain function that automatically compensates for propagation loss of sound CF page 3 7 STC function in TVG CURVE in FUNCTION SETTINGS This STC function enables you to reduce noise interference res...

Страница 36: ...Menu Function Set Menu 3 4 Function Settings Setting Functions 3 5 Gain Up 3 6 TVG Curve 3 7 Dynamic Range 3 7 Pulse Width 3 8 TX Power 3 8 Reduction 3 9 Interference Reduction 3 9 Noise Reduction 3...

Страница 37: ...F 10LOG 20LOG 30LOG 40LOG 1dB 2dB 3dB NARROW NORMAL WIDE 0 3ms LOW HIGH CF page 3 5 REDUCTION INTERFERENCE RED NOISE REDUCTION OFF 1 2 3 OFF ON CF page 3 9 DISP ITEM SEL STEP SONAR 5 10 CF page 3 10 S...

Страница 38: ...ctions are at the desired settings After disconnecting the power supply once by pressing the Power OFF key then turn the power supply back on while pressing both the Operation Mode 1 and the Power ON...

Страница 39: ...customized in the function set menu MAIN MENU FUNCTION SET GAIN UP TVG CURVE DYNAMIC RANGE PULSE WIDTH TX POWER REDUCTION INTERF RED INTERFERENCE REDUCTION NOISE REDUCTION DISP ITEM SEL DISPLAY ITEM S...

Страница 40: ...hift key or REMOTE CONTROLLER Frequency and Version No of EPROM SELF CHECK FUNCTION The test result NG in red is displayed in case of some troubles SETTING FUNCTIONS FUNCTION SET GAIN UP OFF TVG CURVE...

Страница 41: ...is changed from OFF to 10dB the gain dial volume increases 3 points on the scale When the menu gain adjust setting is OFF and the front panel dial is on 3 it has the same result as when the menu gain...

Страница 42: ...rve 3 in the below drawing 40LOG Curve 4 in the below drawing HIGH STC LOW NEAR shallow DISTANCE FAR deep depth In accordance with the distance the gain increases automatically even if the gain volume...

Страница 43: ...e set NARROW WIDE The longer range gives less resolution CONSTANT The initial value of the pulse width is 0 3 ms The pulse width is to be set every 0 1 ms unit from 0 1 to 3 6 ms Use key to select the...

Страница 44: ...evel of the reduction and then press the Enter key OFF indicates this function is inactive As the level of the setting close to HIGH higher level of reduction is set and the level of reducing interfer...

Страница 45: ...FF Press or key to select the desired setting 1 STEP SONAR The step angle scanning angle in the Sonar Mode may be selected Each press of or key changes the setting 5 or 10 Select the desired step angl...

Страница 46: ...tting 3 or 5 Select the desired step angle and then press the Enter key 3 STEP 5 STEP 3 OFF CENTER POSITION The ship s position on the screen may be selected in the OFF CENTER Mode Each press of or ke...

Страница 47: ...ay OFF is selected no scale appears on the screen in the SONAR OFF CENTER Modes SCALE When the scale dots display OFF is selected scale appears on the screen in the Bottom Scan Mode 5 COMPASS DISPLAY...

Страница 48: ...COLOR A 1 FILTER OFF 1 TARGET LOCK This function changes the rotary direction or tracks the target automatically To select the desired Target Lock function when the Target Lock key is pressed in the...

Страница 49: ...le It tracks the echo 10 down Does it pick the echo up Does it pick the echo up YES YES It tracks the echo 5 up It backs to the previous angle Does it pick the echo up Does it pick the echo up NO NO T...

Страница 50: ...raccia br fathoms fm or feet ft Each press of or key changes the setting m br fm ft Select the desired depth unit and then press the Enter key 4 TEMPERATURE UNIT Temperature unit can be set to C or F...

Страница 51: ...t the Bearing toward Bow direction Press the Menu key and select OTHERS Highlight TRAIN CORRECT Press or key to display the degree that you have set in the Sonar mode Press the Enter key BOW DIRECTION...

Страница 52: ...or C 2 and then press the Threshold key to display COLOR PALLET SET Menu Use or key to select the color number from 1 to 8 that you wish to change The levels of the three primary colors red R green G...

Страница 53: ...3 18 FUNCTION SETTINGS 8 FILTER This function provides some smother display of picture image FILTER OFF 1 2 OFF picture image without filter function 1 filter activates 2 a father filter than 1...

Страница 54: ...nitor and hull unit Installation Position 4 2 Dimensions 4 3 Transducer Unit Installation 4 4 Mounting Joint Pipe into Soundome 4 4 Mounting Soundome into TD Case 4 5 Mounting Method of Display Unit 4...

Страница 55: ...owner and dockyard in deciding the location for the hull unit Give careful considerations on mounting INSTALLATION POSITION Select an area where noise bubbles and interference from turbulences are min...

Страница 56: ...4 3 INSTALLATION DIMENSIONS TRANSDUCER UNIT Unit mm OPERATION UNIT...

Страница 57: ...ugh the Joint Pipe Apply some silicone adhesive supplied to the thread of the Joint Pipe see figure 2 below 3 Fully screw the Joint Pipe into the Soundome Clamp the Lock Nut to the Soundome Coat the L...

Страница 58: ...4 5 INSTALLATION MOUNTING SOUNDOME INTO TD CASE...

Страница 59: ...unit on unstable or uneven surface Do not use the unit while tentatively mounted Otherwise it may result in the unit falling or toppling over resulting in injury Be free as much as possible from shoc...

Страница 60: ...Pulling the cables may damage the cables themselves and result in fire or electrical shock Bring wiring to the following attention to avoid getting hurt or causing fire or damage Run the cables not t...

Страница 61: ...L INPUT 2 SIGNAL INPUT 3 GND 4 NC 5 NC Do not connect anything to NC POWER SUPPLY INPUT TERMINAL SOUNDOME TERMINAL 1 DC INPUT 2 DC INPUT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 GND 12V HALL IC OUTPUT T...

Страница 62: ...L REMOTE CONTROL TERMINAL Audio Box Remote controller OP 603 OP 1409 MONITOR TERMINAL 1 RVD 2 GVD 3 BVD 4 NC 5 NC 6 R GND 7 G GND 8 B GND 9 NC 10 GND 11 NC 12 NC 13 H SYNC 14 V SYNC 15 NC 6 1 2 3 4 5...

Страница 63: ...5 1 Chapter 5 OPTION This chapter provides you the explanation related to the optional kits Option 5 2...

Страница 64: ...5 2 OPTION OPTION Parts No NAME MEMO OP 603 Audio Box the audio cable included the audio plug included OP 603 does not include an audio speaker 4 ohm and a speaker cable...

Страница 65: ...er describes you the daily maintenance disposal and specifications of the ESR S1BB Sonar It also provides a memo of operation mode Daily Maintenance 6 2 Disposal 6 3 Specifications 6 4 Remote Controll...

Страница 66: ...and wipe off dust from LCD display lightly with an absorbent cotton or clean soft cloth after removing the filter If there is dust you can not wipe away contact your local dealer or KODEN head office...

Страница 67: ...f heat electrical shock explosion injury or fire DISPOSAL of EQUIPMENT Dispose of this equipment in accordance with local regulations DISPOSAL of LITHIUM BATTERY Before disposing of the lithium batter...

Страница 68: ...Angle Tilt Angle Diagram Sector Angle Display Bearing Angle Ring Marker Historical Distance Slant Distance Depth Gain Up TVG Graph Cross Cursor Bearing Historical Distance Slant Distance Depth Interfe...

Страница 69: ...ard configuration Remote controller connection is made to the terminal on the rear of the operation unit BEARING KEYS Moves cursor center right or left RANGE KEYS TILT KEYS Adjust range Adjust tilt an...

Страница 70: ...WIDE SECTOR NARROW DISPLAY MODE OPERATION 1 OPERATION 2 TARGET LOCK THRESHOLD CURSOR CURSOR UP CURSOR DOWN CURSOR RIGHT CURSOR LEFT NO SETTING HOIST UP HOIST DOWN TILT UP TILT DOWN BEARING RIGHT BEARI...

Страница 71: ...OFF ON DISP ITEM SEL STEP SONAR 5 10 STEP BOTTOM SCAN 3 5 OFF CENTER POS FORE BACK RIGHT LEFT SCALE DOTS OFF ON COMPASS DISP OFF ON OTHERS TARGET LOCK MODE 0 MODE 1 MODE 2 OPERATION MODE 0 1 DEPTH UNI...

Страница 72: ...R G B 6 R G B 7 R G B 8 R G B 9 R G B C 2 1 R G B 2 R G B 3 R G B 4 R G B 5 R G B 6 R G B 7 R G B 8 R G B 9 R G B OPERATION MODE KEY 1 1 C 1 1 R G B 2 R G B 3 R G B 4 R G B 5 R G B 6 R G B 7 R G B 8 R...

Страница 73: ......

Отзывы:

Похожие инструкции для ESR-S1BB