Operating manual Energy storage solutions
V1.3DE/EN
11
2
Description of the device
English
2.7
Ambient conditions
2.8
Electrical supply data
2.9
Dimensions and weight
2.10
Noise emission
The Energy storage solutions do not generate any significant
noise emissions (< 70 dB(A)).
Ambient temperature
-10° C to +65° C (transport, storage)
0° C to +40° C (operation)
Relative humidity
≤
95% (transport, storage)
≤
85% (operation)
Type of cooling
Air cooling (convection)
Separate cooling (for DEx 3.0)
Degree of protection for housing
IP20
Degree of contamination at place of
installation
2
Max. continuous voltage on DC link
800 VDC (DEx)
540 VDC (KEx)
Maximum power
18 kW (DEx)
10.4 kW (KEx)
Standby power dissipation
< 10 W
Usable storage capacity
approx. 1.6 kWs (DES)
approx. 2.0 kWs (DEK, DEV)
approx. 1.3 kWs (KES)
approx. 1.6 kWs (KEK, KEV)
Built-in discharge resistor
PTC (see the enclosed data sheet)
In general, two variants are possible:
PTC800666 and PTC800680K
(Technical data can be found at
www.bremsenergie.de)
Overvoltage category
III (installed at altitudes up to 2000 m
above sea level)
II (installed at altitudes over 2000 m
above sea level)
Immunity to interference
Industrial area
to EN 61000-6-2-2005 and
EN 61000-6-4-2007
Width
100 mm
Depth
201 mm
Height
300 mm
Weight
approx. 6.9 kg
Содержание 2.0 Series