Kobold HND-P210 Скачать руководство пользователя страница 4

HND-P210 

page 4 

 

HND-P210 K08/0422 

5.  Operating Principle 

The KOBOLD manual pressure measuring devices HND-P210 are highly precise, 
compact pressure measuring devices that can be used universally. In conjunction 
with  the  appropriate  external  pressure  sensors,  precise  measurement  results 
over the entire measuring range can be achieved. 
Various  pressure  sensors  are  available  for  a  multitude  of  measuring  tasks  and 
special  applications.  The  respective  measurement  task  determines  which 
combination is selected. Naturally, these first-rate KOBOLD-measuring units can 
display  more  than  just  pressure.  All  devices  in  this  series  allow  for 
minimum/maximum value memory, hold function, automatic self-shut-off, or zero 
point  offset  entry  for  all  connected  pressure  sensors,  for  example.  
The  HND-P210  types  also  have  a  logger  function,  a  peak  value  memory,  or  a 
minimum/maximum alarm. 
 
 
 

6.  Electrical Connection 

Mains Operation With Power Supply 

Warning: When using a power supply please note that 
operating voltage has to be 10.5 to 12 V

DC

. Do not apply 

overvoltage!! Cheap 12 V-power supplies often have 
excessive no-load voltage. We, therefore, recommend using 
regulated voltage power supplies. Trouble-free operation is 
guaranteed by our power supply HND-Z002. 

Prior to connecting the power supply to the mains make sure that the operating 
voltage stated at the power supply is identical to the mains voltage.

 

 
Connecting/Changing Sensors 

Do not use insuitable sensors. Connecting other devices/sensors as specificated 
may  cause  a  damage  to  the  instrument  and  device/sensor!  Switch  off  device 
before  changing  the  sensor.  Connect  sensor  before  switching  on  the  device, 
otherwise the sensor may not be detected correctly. When connecting the sensor, 
the connector may not lock correctly. In such case take the plug not at the casing 
but at the buckling protection at the end of the plug. If plug is entered correctly, it 
will slide in smoothly. To disconnect sensor do not pull at the cable but at the plug 
(to open locking mechanism). 

 
 

Содержание HND-P210

Страница 1: ...Operating Instructions for Hand held Pressure Measuring Devices for External Pressure Sensors Model HND P210...

Страница 2: ...r Level Display Unit m 11 8 6 Operation Of Logger 11 8 7 The Serial Interface 14 8 8 Pressure Connection to The Sensors 15 8 9 Error and System Messages 16 8 10 Calibration Services 16 9 Maintenance 1...

Страница 3: ...iced by persons familiar with these operating instructions and in accordance with local regulations applying to Health Safety and prevention of accidents When used in machines the measuring unit shoul...

Страница 4: ...eration With Power Supply Warning When using a power supply please note that operating voltage has to be 10 5 to 12 VDC Do not apply overvoltage Cheap 12 V power supplies often have excessive no load...

Страница 5: ...e the device temperature has adjusted to the ambient temperature before trying a new start up 4 If device is to be connected to other devices e g via serial interface the circuitry has to be designed...

Страница 6: ...Furthermore the kind of measuring is displayed Slo Fast P det p r t 2 1 and Corr if a Sensor with activated offset or scale correction is connected After changing the battery the clock setting menu is...

Страница 7: ...tment press button 3 for approx 5 seconds Auto Null will be displayed shortly The adjustment is done via the OFFSET value of the sensor referring configuration menu Note A zero point adjustment can on...

Страница 8: ...mbar Enter desired value at which the analogue output potential should be 1 V if Out dAC Set CAL Set Calibration Adjustment of Sensor OFFS Sensordep e g 5 00 5 00 mbar The offset of sensor will be dis...

Страница 9: ...Application with logger function Measuring of short pressure peaks or fast changing pressures with a resolution of 1ms The cyclic logger function records the arithmetic mean value the highest and the...

Страница 10: ...rface converter To get access to each device the base addresses of the devices have to be different For example choose 01 for the first 11 for the second device and so on See also chapter 8 7 The Seri...

Страница 11: ...tore 2 seconds The logger records 3 measurement results each time current or mean value depending on logger setting see below min peak and max peak of sensor Min and max peak are the minimum resp the...

Страница 12: ...etween the different values referring to the measurement also is done by pressing Changing the measurement is done by pressing the keys or 8 6 2 Func CYCL Automatic Recording With Selectable Logger Cy...

Страница 13: ...ording Do not stop the recording The selection can be made by key 2 and key 5 Quit key 6 enters the choice Note If you try to switch off the instrument in the cyclic recording operation You will be as...

Страница 14: ...me Conf P oFF x 12 Read ID number x 223 Set power off time Conf P oFF x 22 Read min alarm rail AL AL Lo x x 224 Logger Read data of CYCL Logger x 23 Read max alarm rail AL AL Hi x 225 Logger Read cycl...

Страница 15: ...e measuring range by re plugging the tube to pressure port A Please note that all values are displayed as positive values No minus sign will be shown Example for HND PS02 For tube connection B the mea...

Страница 16: ...Sensor defective Return to manufacturer for repair Err 2 Measured value below allowable range Check pressure not within sensor range measuring value to low Sensor defective Return to manufacturer for...

Страница 17: ...ensor Accuracy typ 0 1 F S at nominal temperature FASt and P dET 0 5 FS Measuring rate slow 4 meas sec ConF Rate slow fast 1000 meas sec ConF Rate FASt and P dEt Nominal temperature 25 C Sensor All se...

Страница 18: ...consumption Slow measuring rate 1 6mA Fast measuring rate 7 0mA Low Power Logger 0 3mA for cycle time 30s without interface communication active and no alarm horn sounding up to 0 8mA at cycle time 1s...

Страница 19: ...HND P210 HND P210 K08 0422 page 19 11 Order Codes Order no Housing design HND P210 1 x pressure sensor input with additional functions...

Страница 20: ...S06 0 2000 mbar abs HND PS07 0 7 00 bar abs 10 mbar max 10 bar abs HND PS08 0 400 0 mbar rel 0 1 mbar max 2 bar rel 0 70 C External threads G Edelstahl HND PS19 0 1000 mbar rel 1 mbar max 5 bar rel HN...

Страница 21: ...olated HND Z033 Adapter RS232 converter on USB interface HND Z034 Windows software for setting and data read and print out of instruments of the HND series with logger function BUS S20M Software for r...

Страница 22: ...ds noted below EN 61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requirements Part 1 General requirements EN IEC 63000 2018 Technical documentation for the assessment...

Отзывы: