![Kobold Heinrichs BGK Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/kobold/heinrichs-bgk/heinrichs-bgk_operating-instructions-manual_1982426010.webp)
Heinrichs Messtechnik GmbH
Operating manual KDS/BGK
January 2021
7
Electrical output
7.1
Limit switches
1 or 2 limit switches:
Manufacturer: Pepperl & Fuchs
Type:
NJ1.5-6.5N,
Connection:
M12 plug
Ex-Marking:
PTB 00 ATEX 2048 X
II 2G Ex ia IIC T6-T4 Gb
II 2D Ex ib IIIC T 135°C Db
OR
1 limit switch (safety technology):
Manufacturer: Pepperl & Fuchs
Type:
NJ2-11-SN,
Connection:
M12 plug
Ex-Marking:
PTB 00 ATEX 2049 X,
II 2G Ex ia IIC T6-T4 Gb,
II 2D Ex ia IIIC T135°C Db,
7.2
Analogue output
4-20 mA, current loop, passive
Manufacturer: Heinrichs Messtechnik
Type: KDS-E, (Uo = 14-30 V; Max. load 500
Ω
,)
Connection:
M12 plug
Ex-Marking:
BVS 12 ATEX E 093 X / IECEx BVS 12.0061X
II 2G Ex ib IIC T4 Gb
II 2D Ex ib IIIC T135°C Db
When installing electrical equipment in hazardous areas please pay special attention to the conditions
specified in the applicable approval certificate.