DSS
Page 16
DSS K08/0322
11. Technical Information
Housing:
DSS-11.. :
brass, Ms 58
DSS-12.. :
st. st., 1.4301
Connections:
DSS-11.. : brass, Ms 58
DSS-12.. : st. st., 1.4301
Float:
DSS-11.. : brass, Ms 58
DSS-1101: PP
DSS-12.. : st. st., 1.4301
DSS-1201: PVDF
Nozzle:
DSS-11.. : brass, Ms 58
DSS-12.. : st. st., 1.3955
O-rings:
DSS-11.. : NBR
DSS-12.. : FPM
Max. temperature:
100 °C
DSS-1101.., DSS-1201.. : 70 °C
Max. pressure:
DSS-1101.., DSS-1201..: 16 bar
DSS-11.. : 250 bar
DSS-12.. : 350 bar
Installation position:
vertical, upward flow
Accuracy:
± 5% of full scale
Repeatability:
≤ 1%
Contact:
bistable reed contact
Electrical connection:
2 m cable (DSS-F0..)
for all other models:
Connector DIN EN 175301-803
Electrical switching values:
N/O contact:
max. 250 V
AC/DC
/ 1.5 A / 100 W / 100 VA
Changeover contact:
max. 250 V
AC/DC
/ 1 A / 30 W / 60 VA
N/O contact and changeover
contact (cCsAus):
max. 230 V
DC
/ 0.26 A / 60 W, 60 V
DC
/ 1 A / 60 W
max. 240 V
AC
/ 0.42 A / 100 W, 100 V
AC
/ 1 A / 100
Use in hazardous areas
Mechanics:
The apparatus can be used as follows in
explosive atmospheres in accordance with the
applicable erection regulations on machines,
devices and plants, such as e.g. EN 1127-1,
EN 60079-14 etc.:
a) In Zone 1 (gas hazard, category 2G) in the
explosion groups IIA, IIB and IIC
b) In Zone 2 (gas hazard, category 3G) in the
explosion groups IIA, IIB and IIC
c) In Zone 21 (dust hazard, category 2D) in the
explosion groups IIIA and IIIB
d) In Zone 22 (dust hazard, category 3D) in the
explosion groups IIIA and IIIB
Содержание DSS -11
Страница 1: ...Operating Instruction for Flow Monitor Model DSS...
Страница 22: ...DSS Page 22 DSS K08 0322 17 EU Declaration of Conformance reed contact 41R57 ATEX not available in GB...
Страница 23: ...DSS DSS K08 0322 Page 23 18 Statement of conformity reed contact 41R57 ATEX not available in GB...
Страница 24: ...DSS Page 24 DSS K08 0322 ATEX not available in GB...
Страница 25: ...DSS DSS K08 0322 Page 25 ATEX not available in GB...
Страница 26: ...DSS Page 26 DSS K08 0322 ATEX not available in GB...
Страница 27: ...DSS DSS K08 0322 Page 27 19 Declaration of the Manufacturer F0 ATEX not available in GB...
Страница 28: ...DSS Page 28 DSS K08 0322 20 EC Type Examination Certificate Magnetic reed switch F0 ATEX not available in GB...
Страница 29: ...DSS DSS K08 0322 Page 29 ATEX not available in GB...
Страница 30: ...DSS Page 30 DSS K08 0322 ATEX not available in GB...
Страница 31: ...DSS DSS K08 0322 Page 31 21 IECEx certificate F0 ATEX not available in GB...
Страница 32: ...DSS Page 32 DSS K08 0322 ATEX not available in GB...
Страница 33: ...DSS DSS K08 0322 Page 33 ATEX not available in GB...
Страница 34: ...DSS Page 34 DSS K08 0322 ATEX not available in GB...
Страница 35: ...DSS DSS K08 0322 Page 35 ATEX not available in GB...
Страница 36: ...DSS Page 36 DSS K08 0322 ATEX not available in GB...