NSTALLATION
It is recommended that any required service work on a Kobelt unit
be performed by a factory authorized service representative. Please
contact the nearest Kobelt authorized distributor for assistance.
Steps for replacement of spring and seals:
1.
Loosen cable gland.
2.
Remove housing screws and cover plate.
3.
Unthread handle shaft and remove shaft hub.
4.
Remove spring arms (with spring and spring bushing attached).
5.
Remove shaft assembly (be careful not to lose spacer).
6.
Remove and replace small housing O-rings (4x). Refer to Figure 8.
7.
Remove and replace large housing O-ring.
8.
Remove and replace shaft O-ring.
9.
Disconnect spring from spring arms.
10.
Slide bushing onto new spring and re-attach to spring arms.
11.
Reassemble unit as shown in Figure 7.
a.
Use Loctite 242 or 243 on handle shaft threads and housing screw threads.
b.
Ensure shaft has sufficient assembly grease (add more if necessary).
c.
Refer to Figure 9 for spring arm orientation/order.