30
)81&7,21
6<67(0
02'(/ 7,0(5
.(<6(7
7506(7
؞ڰ&+
START : POS1
3CH MODE : 2WAY
KEY : OFF
+
ー
POS1 : 0
POS2 : 100
3CH MODE
3・4CH
4CH MODE
GYRO
TWIN
4WS
AMP
T-MIX
OFF
2WAY
3WAY
5WAY
ANLOG
5WAY
SET
2WAY
SET
3・4CH menu
Settings related to 3CH and 4CH operations.
The MODE of 3CH or 4CH s selected from the right.
Change the setting of the item chosen with the SET key.
The functions which may be set are the same for both
3CH and 4CH. Set them to match the desired purpose.
P
▶ 2WAY MODE
Modify the 2-interval output settings.
【Setting Range】
START:POS 1、POS 2
((Default:POS 1)
Sets the starting position.
KEY:OFF、ET1 〜 5
((Default:OFF)
Assigns a key to use for switching positions.
POS 1:-100 〜 100
((Default:0)
Sets Position 1's output position.
POS 2:-100 〜 100
((Default:100)
Sets Position 2's output position.
【Default】
3CH MODE : 5WAY
4CH MODE : 2WAY
《Functions》
▶ MODE
OFF
2WAY
3WAY
5WAY
ANLOG
▶ SET
Set the usage choice for channels 3 and 4 modes.
GYRO
TWIN
4WS
AMP
T-MIX
【Example】
May be used to activate/deactivate an engine starter
unit or a semi-trailer's support legs.
START : POS1
3CH MODE : 3WAY
KEY : ET3
SET
+
ー
POS1 : -100
POS2 : 0
POS3 : 100
▶ 3WAY MODE
Modify the 3-interval output settings.
【Example】
May be used for gear changing operations or when
you wish to set a 3-interval control scheme for the
servo.
【Setting Range】
START:POS 1、POS 2、POS 3
(Default:POS 2)
Initial position is configurated.
KEY:OFF、ET1 〜 5
(Default:OFF)
Assigns a key to use for switching positions.
POS 1:-100 〜 100
(Default:-100)
Sets Position 1's output position.
POS 2:-100 〜 100
(Default:0)
Sets Position 2's output position.
POS 3:-100 〜 100
(Default:100)
Sets Position 3's output position.