94
Utilisation conforme
Plaque signalétique et plages de mesure du P52100
Commutation calibrée de la sortie sur le
commutateur rotatif S2
Commutation calibrée de la
sortie sur le commutateur
rotatif S1
Exemple
Plaque signalétique UL
Exemple
Type
No.
ES01
00000
14163 Berlin Made in Germany
P52100K11-M6M/11
0000000
Made in Germany
14163 Berlin
Type P52100K11-M6M/11
0000000
No.
ES01
ProLine
High-Voltage Transducer
nnnnn / 0000000 / jjww
Output
(Input Bipolar)
Output
(Input Unipolar)
Switch
Switch
S1
S1
±10
10
±5
5
1800
4200
1500
3600
4 to 20
4 to 20
±20
0 to 20
0 to
0 to
1200
3000
1000
2500
900
2000
Switch
Switch
Input
(End of Scale)
S2
S2
mA
mA
mA
mA
V
V
V
V
V
V
V
V
V
V
V
V
V
V
3
2
2
6
6
2
1
8
5
9
1
0
0
4
4
0
10Hz
10Hz
8
7
6
5
9kHz
9kHz
4
3
3
7
7
9
Operating Temperature
Power
24 to 230 V AC (50/60 Hz) / DC
DC: -30 % / +10 %, 2.5 W
AC: -20 % / +10 %, 6 VA
Input - Output/Supply
Isolation
Routine Test Output - Supply
kV
kV
16
4
8
9
10
Power
Diagnostics Monitor
Output
7
6
5
4
3
2
1
I/U
Diag
Power
I
U
+
+
R
C
E
S2
S1
M
I
M
I
Additional Input Ratings to UL 347
* AC (45 to 66 Hz) / DC Overvoltage Cat. III,
Pollution Degree 3
Contains no serviceable parts.
Use copper wires only.
HIGH VOLTAGE INDUSTRIAL CONTROL
EQUIPMENT ACCESSORY E356768
30 mV to 120 V
30 mV to 120 V
100 V to 2000 V
100 V to 4200 V
P510*
P511*
P520*
P521*
<50 µA
<50 µA
>1 M (0,4 VA)
>1 M (1,1 VA)
2200 V 30 kV
3600 V 30 kV
2200 V 30 kV
4800 V 33 kV
Input Ranges
Types
Input Load Rated
Isolation*
BIL
LISTED
UL
®
40 to +85 °C
E356768
LISTED
UL
®
Type
No.
ES01
00000
14163 Berlin Made in Germany
P52100K11-M6M/11
0000000
Made in Germany
14163 Berlin
Type P52100K11-M6M/11
0000000
No.
ES01
ProLine
High-Voltage Transducer
nnnnn / 0000000 / jjww
Output
(Input Bipolar)
Output
(Input Unipolar)
Switch
Switch
S1
S1
±10
10
±5
5
1800
4200
1500
3600
4 to 20
4 to 20
±20
0 to 20
0 to
0 to
1200
3000
1000
2500
900
2000
Switch
Switch
Input
(End of Scale)
S2
S2
mA
mA
mA
mA
V
V
V
V
V
V
V
V
V
V
V
V
V
V
3
2
2
6
6
2
1
8
5
9
1
0
0
4
4
0
10Hz
10Hz
8
7
6
5
9kHz
9kHz
4
3
3
7
7
9
Operating Temperature
Power
24 to 230 V AC (50/60 Hz) / DC
DC: -30 % / +10 %, 2.5 W
AC: -20 % / +10 %, 6 VA
Input - Output/Supply
Isolation
Routine Test Output - Supply
kV
kV
16
4
8
9
10
Power
Diagnostics Monitor
Output
7
6
5
4
3
2
1
I/U
Diag
Power
I
U
+
+
R
C
E
S2
S1
M
I
M
I
Additional Input Ratings to UL 347
* AC (45 to 66 Hz) / DC Overvoltage Cat. III,
Pollution Degree 3
Contains no serviceable parts.
Use copper wires only.
HIGH VOLTAGE INDUSTRIAL CONTROL
30 mV to 120 V
30 mV to 120 V
100 V to 2000 V
100 V to 4200 V
P510*
P511*
P520*
P521*
<50 µA
<50 µA
>1 M (0,4 VA)
>1 M (1,1 VA)
2200 V 30 kV
3600 V 30 kV
2200 V 30 kV
4800 V 33 kV
Input Ranges
Types
Input Load Rated
Isolation*
BIL
40 to +85 °C
E356768
LISTED
UL
®
WWW.OCTSOURCES.COM
Содержание P51000K11-M1M/11