74
Specifications
EN 50124-1, IEC 62497,
EN 50178
Max.
1000 V AC/DC
Rated impulse voltage: 20 kV
Contact protection
(protection against
electric shock)
Max.
1000 V AC/DC
with ZU 1030 protective covers,
ZU 1031 cable support sleeves
acc. to EN 50153 ranges I to III
Clearances
Min. 60 mm
Creepage distances
Min. 90 mm
CTI 600, insulant group I acc. to
EN 50123-1, EN 50124-1
Isolation
Output against Power Supply
Test voltage
4 kV
100 % routine test / type test
Rated isolation voltage
Protection against
electric shock by
reinforced insulation
Overvoltage category OV3,
pollution degree PD3
for EN 50178: PD2
EN 50124-1, IEC 62497,
EN 50178,
EN 61140/EN 61010-1, UL347
Max.
300 V AC/DC
Rated impulse voltage: 6.4 kV
Ambient Conditions
Temperature class
TX
EN 50125-1,
EN 50155
Operating temperature
–40 ... 85 °C
Storage temperature
–50 ... 90 °C
Relative humidity
20 ... 95 %
Limit values for continuous operation
75 %
Annual average
95 ... 100 %
Occasional
Altitude classes
A1, AX
EN 50125, reduced isolation level
for heights of 2000 to 4000 m AMSL
Air pressure during
operation
600 ...
1060 hPa
WWW.OCTSOURCES.COM