27
Condensate Drain
Ceramat® WA 160(X) Retractable Fitting
Functioning of the Condensate Drain
Water that has condensed in the fitting collects in the
lower part of the immersion tube
(A)
. This area is con-
nected to the channels of cavity rinsing
(C)
through
a spring-loaded check valve
(B)
. When the fitting is in
PROCESS position, these channels are always connected
to the outlet
(D)
. If now (in PROCESS position!) pressure is
applied to the pneumatic connection
(E)
above the flange,
the condensate will be drained out of the fitting through
the check valve and the outlet.
The Ceramat WA 160(X) retractable fitting is equipped with a condensate drain.
Specifications:
Barometric
pressure:
4 bar recommended (max. 5 bar)
Connection:
Threaded joint with hose nipple
and coupling nut (torque: 5 Nm)
for DN6 hose
E
D
A
E
B
C