
EN
| 14
EN
| 15
Does not act analgesically!
The Gentler has a time-controlled automatic shut-off which automati-
cally turns off the device after 1 hour of inactivity; all the LEDs flash at
short intervals 1 minute prior to the automatic shut-off. If you press a
key during this time, the automatic shut-off is delayed by one more
hour.
Begin the treatment or grooming.
To terminate the immobilization, press and hold the minus button [10]
for 2 seconds to turn off the Gentler. Now pull the probe out of the
rectum of the animal. The animal will return to its normal state after the
Gentler is switched off.
Fig.4
The device has one (1) pcs. Industry quality battery.
The operating time of the fully charged batteries is approximately 8
hours (depending on the duration of use).The battery charge status
indicator [11] has 3 LED diodes which signal different states.
1.
All 3 LED diodes lit green:
Battery is fully charged.
2.
The lower 2 LED diodes lit green:
Battery is half full.
3.
The bottom LED lit green:
Battery is charged to one third.
4.
The bottom LED is red:
Some days before use, dry feed is to be avoided during the
feeding of the animals, since this can lead to a dry bowel and
reduced conductivity of the electrical signal at the treatment site.
Battery is not charged and the device must not be used.
Regular rechargeable battery recharging is required after
2 months at the latest.
Not a substitute for anesthetics!!!
It is the responsibility of the user to utilize the GENTLER applica-
tion purely for the immobilization of the animal. The device must
not be used as a substitute for anesthetics during, for example,
surgical procedures.
It does not therefore replace the use of
conventional anesthetics.
Technical specifications
Length:
401,4 mm
Height:
141 mm
Width (Grip):
51,15 mm
Diameter (Electrode):
32 mm
Weight:
390 Gram
Battery type:
2500 mAh, 3,7V
Input voltage:
9 - 12V DC
Input current:
2A
Output voltage:
5-17V @32Hz