13.12. Troubleshooting
PROBLEM
CAUSE
SOLUTION
Machinery without power
supply
Emergency button pressed
Check the button
Disconnected power cables
(behind emergency button)
Check connections.
.
No thrust forward or
poor thrust backward.
Flat battery
See display
Worn brushes
Check wear
Unsuitable brushes for the floor
Check type
.
Poor water collection or
no water collection
Wiper not adjusted
Adjust the wiper
Wiper clogged by debris
Remove debris
Worn wiper blades
Rotate or replace the blades
Water collection flexible hose
clogged
Release the vacuum flexible hose
Water collection flexible hose
not correctly inserted in the
recovery tank
Reconnect the
vacuum flexible hose.
Water collection flexible hose
damaged
Replace the flexible hose.
Recovery tank not
hermetic.
Replace damaged seals
(gaskets)
Recovery tank full of foam
Empty the recovery tank,
use less detergent or a
different detergent.
Use an anti-foaming agent.
.