![Kleinn Air Horns GMTRK-3 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/kleinn-air-horns/gmtrk-3/gmtrk-3_install-manual_1977502036.webp)
GMTRK-3
Install Guide
This Install Guide Replaces the
GMTRK-1 Installation Manual
REV: B (09/07/2022)
36
11
General Operation
11.1
Compressor Operation
WARNING
: NEVER operate the air compressor above its MAXIMUM PRESSURE RATING (see label on body). Operation
exceeding maximum pressure will damage the compressor and potentially cause air system failure.
1.
Kleinn’s oil-less compressor is equipped with an automatic thermal overload protection circuit designed to
protect the air compressor from overheating and causing permanent damage.
2.
Automatic thermal overload protector will reset after 30 minutes.
3.
To prevent discharge of the vehicle’s battery, and for best performance, keep the vehicle’s engine running
while using the air compressor for any prolonged use.
11.2
Horn Operation
1.
Allow the air compressor to run until it shuts off automatically, (i.e., air tank is full) or for at least one
minute between horn activations.
2.
Press the horn button to activate the horns
3.
Horn sound/loudness will diminish as the pressure in the air tank decreases.
WARNING
: NEVER operate train horns with ears near trumpets or in an enclosed space without
all persons closer than 100 feet from vehicle. Never operate train horns outdoors when persons are near vehicle
without hearing protection.
END OF SECTION