There are two ways to carry out the connection to the main gas line:
A. The freestanding cooker can be connected with rigid pipe as specified in AS/NZS 5601 .
B. The cooker can be connected with a Flexible Hose, which complies with AS/NZS 1869
(AGA Approved), 10mm ID, class B or D, not more than 1.2m long and in accordance with
AS/NZS 5601. Ensure that the hose does not contact the hot surfaces of the hob, oven,
dishwasher or other appliances that may be installed underneath or next to the cooker.
WARNING: Ensure that the hose assembly is not in contact with the flue or flue outlet of the
oven. The hose should not be subjected to abrasion, kinking or permanent deformation and
should be able to be inspected along its entire length. Unions compatible with the hose
fittings must be used and connections must be tested for gas leaks. The supply connection
point shall be accessible after the appliance is installed. The fixed consumer-piping outlet
should be at approximately 150mm to the side of the cooker. The hose should be clear of the
floor when the cooker is installed.
CAUTION !!
Carry out the connection without applying any kind of stress to the appliance.
Warning:
The restraint chain supplied should be anchored to the wall so that the chain
prevents strain on the hose connections when the cooker is pulled forward.
After gas connection, check for leaks using soapy solution, never a naked flame.
Setting of the gas pressure
Fit a manometer with a 6mm rubber hose to the test point on the NG regulator. Or fit the
manometer to LPG test point if ULPG connection is used.
Ignite the wok and auxiliary burner on and adjust test point pressure to 2.75kPa for ULPG
and 1.00kPa for NG. Turn the two burners off and on again and recheck the pressure if it is
the same as previously set. Adjust again if required.
Test if the cooktop operates correctly
After installation and test point setting, each burner ignition and operation must be tested
individually and with all burners operating. This testing must be done by the installer before
leaving.
Supplied Gas Conversion
Contact the manufacturer or authorised dealer for conversion. For service, please refer to
contact details in the warranty card.
Important:. Before carrying out the conversion, unplug the appliance from the gas and
power mains.
Replacing nozzles :
-
Unplug the appliance from the mains to avoid possible electrical shock.
-
Remove the trivets from the hob
-
Remove the burner caps
-
Use a 7mm tubular hex wrench to loosen the nozzles and replace them with suitable
nozzles as indicated in the diagram below.
-
Remove or install regulator for NG or test point adaptor for ULPG.
Page 8
V 2.0